4.1.2 Foundation requirements
Requirements
•
The location and size of the foundation bolt holes must match those shown on the assembly draw-
ing provided with the pump data package.
•
The foundation must weigh between two and three times the weight of the complete pump, base-
plate, and drive assembly.
•
Provide a flat, substantial concrete foundation in order to prevent strain and distortion when you
tighten the foundation bolts.
Sleeve-type bolts
1
2
3
4
5
6
Item Description
1.
Baseplate
2.
Shims
3.
Foundation
4.
Sleeve
5.
Dam
6.
Bolt
Figure 11: Sleeve type bolts
J-type bolts
1
3
2
4
5
Item Description
1.
Baseplate
2.
Shims or wedges
3.
Foundation
4.
Dam
5.
Bolt
Figure 12: J-type bolts
4.1 Pre-installation
24
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...