Frame
Initial grease in grams | ounces
Regrease
1
in grams | ounces
Thrust (angular contact) Radial (cylindrical roller) Thrust (angular contact) Radial (cylindrical roller)
M
290 | 10
7 (180)
115 | 4
70.0 | 2.5
L
475 | 17
10 (280)
200 | 7
115 | 4
XL
800 | 28
16 (450)
345 | 12
190.0 | 6.5
1
The regrease amount is based on purging half of the old grease from the housing reservoir. Not availa-
ble on the XL1, XL2-S, and XL2 sizes.
6.2.2.1 Regrease the grease-lubricated bearings
NOTICE:
Risk of equipment damage. Ensure that the grease container, the greasing device, and the fit-
tings are clean. Failure to do so can result in impurities entering the bearing housing while re-
greasing the bearings.
1.
Wipe dirt from the grease fittings.
2.
Remove the two grease-relief plugs from the bottom of the frame.
3.
Fill both of the grease cavities through the fittings with a recommended grease until the fresh
grease comes out of the relief holes.
4.
Make sure that the frame seals are seated in the bearing housing.
If they are not, press them in place with the drains located at the bottom.
5.
Run the pump for about 30 minutes or until grease no longer comes out of the housing.
6.
Reinstall the grease-relief plugs.
7.
Wipe off any excess grease.
8.
Recheck the alignment.
The bearing temperature usually rises after you regrease due to an excess supply of grease. Tempera-
tures return to normal in about two to four operating hours as the pump runs and purges the excess
grease from the bearings.
6.2.3 Lubricate the bearings after a shutdown period
1.
Flush out the bearings and bearing frame with a light oil to remove contaminants.
During flushing, make sure to rotate the shaft slowly by hand.
2.
Flush the bearing housing with the proper lubricating oil to ensure oil quality after cleaning.
3.
Refer to
Reassembly
section for proper bearing greasing procedure.
6.2 Bearing maintenance
74
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...