If your pump
group is...
Then...
XL1, XLS-2,
and XL2
Install the seal chamber (184) and hex head bolts (370H) on the frame adapter (108).
108
370H
418
184
351
126
6.
Slide the cartridge seal on the gland studs and make sure that the tap connections are in the cor-
rect orientation.
7.
Hand-tighten the gland nuts.
8.
Install the impeller and set the clearance.
9.
Set the seal:
a) Tighten the set screws in the drive collar while the setting clips are engaged.
b) Tighten the gland nuts (355) evenly.
c)
Disengage the setting clips.
6.6 Reassembly
104
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...