4.2 Baseplate-mounting procedures
4.2.1 Prepare the baseplate for mounting
1.
Remove all the attached equipment from the baseplate.
2.
Clean the underside of the baseplate completely.
3.
If applicable, coat the underside of the baseplate with an epoxy primer.
Use an epoxy primer only if using an epoxy-based grout.
4.
Remove the rust-proofing coat from the machined mounting pads using an appropriate solvent.
5.
Remove water and debris from the foundation-bolt holes.
4.2.2 Install the baseplate using shims or wedges
Required tools:
•
Two sets of shims or wedges for each foundation bolt
•
Two machinist's levels
•
Baseplate-leveling worksheet
This procedure is applicable to cast iron and fabricated steel baseplates.
1.
If you use sleeve-type bolts, fill the bolt sleeves with packing material or rags to prevent grout from
entering the bolt holes.
2.
Put the sets of wedges or shims on each side of each foundation bolt.
The sets of wedges should have a height of between 19 mm | 0.75 in. and 38 mm | 1.50 in.
1
1.
Shims or wedges
Figure 13: Top view
1
1.
Shims or wedges
Figure 14: Side view
3.
Lower the baseplate carefully onto the foundation bolts.
4.
Put the machinist's levels across the mounting pads of the driver and the mounting pads of the
pump.
NOTICE:
Remove all dirt from the mounting pads in order to ensure that the correct leveling is achieved.
Failure to do so can result in equipment damage or decreased performance.
4.2 Baseplate-mounting procedures
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
25
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...