7. Installation/Wiring
24
MABS technical document
Safety precautions
Advanced preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Troubleshooting
Appendix
IB-E06F-M1 settings
7-1.
Before installation
Before installation
■
For position of sensor
which is assigned as
trigger for ball turning,
perform transfer test in
advance, and determine
after adjusting to the
appropriate position.
Load C/V
Load C/V
Discharge C/V
Discharge C/V
①
Area sensor
(Load)
Divert C/V
Divert C/V
③
Area sensor
(Discharge)
②
Area sensor
(Divert)
④Zone sensor
④Zone sensor
④
Zone sensor
About the MABS main unit
installation position and
diverting conveyor
③
Install the MABS main units to be
combined by securing a space of 5 mm.
④
Provide the adjustment margin of
approximately 50 mm between the MABS
main unit and upstream/downstream
conveyors.
①
Mount the loading area sensor on the
upstream side of the MABS main unit.
②
Mount the area sensor used to check
discharging on the diverting side, at the
boundary of the straight conveyor and
diverting conveyor.
③
Mount the area sensor used to check
discharging on the straight side, in the
most downstream of the diverting
section.
④
Mount the zone sensor used to check the
presence of totes in the diverting section
(on the MABS main unit).
About area and zone
sensors
①
W
④
50 mm
(adjustment margin)
④
50 mm
(adjustment margin)
②
100mm
Dimension between
frames of Divert C/V
③
5mm
①
W+200mm
Transfer direction
Transfer direction
Prepare the frame by refering to the following instructions, as well as for mounting holes
and stays.
①
Prepare the diverting conveyor to be wider
than the straight conveyor W + 200 mm
(The conveyor width depends on totes
and/or tote position.)
Install the MABS main unit in the position as
described in the figure.
②
Refer to the following instructions, and and prepare frames so that sensors can be
mounted.
Original notice - U1.1