27
7. Installation/Wiring
MABS technical document
Safety precautions
Advanced preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Troubleshooting
Appendix
IB-E06F-M1 settings
Size 600
L186mm×W598mm
Size 600
※
Guide for cable marginal projecting length
(
mm
)
M1 : Motor of Transfer balls
M2 : Motor of Swing
SA : Proximity sensor (Origin)
80
80
80
■
The origin sensor cable needs to be extended.
The machine height and height of the mounting surface indicate
dimensions at the time of the actual transfer (when load is applied
to transfer balls).
4
ー
M8
(Weld nut for
mounting main unit)
4
ー
M5×6
(
Bolt for mounting
a top cover
)
(Pitch between
mounting screws)
(Height of the mounting
surface from the stay)
570(Pitch between mounting screws)
154
16
14
598
99
400=P100×4(Pitch between balls)
49
500=P100×5(Pitch between balls)
186
175
7.8
49.7
86.7
10
0
+0.5
+2.5
91
131
4
ー
M5×6
(Bolt for mounting a bottom cover)
94
±1
wiring hole
wiring hole