Turn the row with the less transfer balls to the
upstream side, and place on the stays.
3
Row of less
transfer
balls
■
When installing, be careful not to get
fingers caught.
■
Install this product in places with a
mounting surface tilt (inclination) of 0.5%
or less.
■
The vibration level in the installation
environment for this product should be
0.5G or less.
■
Observe safety regulations required for
installation locations or equipment in
use.
■
Install in locations where the weight of
this product and totes can be sufficiently
supported.
(For the main unit weight, refer to P.70)
MABS
Stay
Upstream side