4-60
Getting Started
Chapter 4
Set Options
The options available for the recorder are installed on the recorder CPU with so-
called option modules. These option modules are plugged onto the PC-board. In
chapter 3 "Installation - Recorder installation" all option modules are shown in fig.7.
All options installed in the recorder have to be released via the option setting routine.
This routine can be started when the recorder is switched on and the key "
R
" is
pressed simultaneously until column change and card lift adjustment is finished. The
options available and their status can be defined.
Hint
The option "Check of individuals" cannot be released via this
routine. See paragraph "Check of individuals" on the following
pages.
Proceeding
1.
Switch recorder off.
2.
Keep "
R
" pressed and switch recorder on.
Keep "
R
" pressed until synchronisation of the
analogue clock has finished.
3.
D1
D2
D3
Select status with "
R
", field D3.
Definition:
D1 = 01 = slave clock function
= 02 = DCF-connection
= 03 = Standby operation
= 04 = Master clock function
= 05 = Card face control
D3 = 00 = Option disabled
= 01 = Option enabled
Value range: 00 - 01
4.
Confirm setting with "
E
".
Recorder switches to next option.
5.
Repeat steps 3 and 4 for further options.
.
If master clock function is released,
continue with step 6.
.
If the master clock function is blocked,
the recorder returns to normal operation
after the last digit has been confirmed with
"
E
". Current date is displayed.