5.6.2
AUX
AUX section allows users to change AUX stop mode and smart filtration start
settings.
Smart filtration start: <value> Value in minutes. Smart filtration feature is
starting filtration pump when AUX or lights are active outside filtration time.
This settings allows user to define time after which filtration is started when
AUX or lights are switched on.
AUX autostop mode:
Automatic – LVLØ system will automatically stop AUX after defined time
Manual – AUX start and stop are only based on customer triggers.
AUX autostop time: <value> value in minutes. When AUX autostop mode is
in automatic mode, LVLØ will automatically stop AUX after the preset time.
After performing setup or any changes to this section, click „SAVE SETTINGS”
to save configuration to system.
5.6.3
Water treatment
Water treatment section is used when chemical barrels are changed and
also to define threshold for Chemical stocks alert. In this section you can
define chemical barrel volume, see actual barrel usage and volume left in
barrel for each of used chemicals.
<Chemicals> barrel volume: <value> value in liters. Set volume of chemical
barrel that is installed.
<Chemicals> barrel actual usage: Displays volume in liters that was used
from installed volume.
<Chemicals> barrel left: Displays volume in liters left from installed volume.
<Chemicals> barrel change: <button> Set barrel usage counters to zero and set barrel volume value as
countdown value.
<Chemicals> reset counter: <button> reset counter to initial values.
Stocks alert threshold: <value> value in days. Define number of days in which
the LVLØ system will start warning before chemicals will need to be
replaced.
pH or ORP correction: <value>. Value that will be added to measured value
of pH or ORP by the system. Value on the device display will show measured value, and mobile application
and system will be working with adjusted value.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to