Press the recessed area (1.) to open the lid (2.) over 180°. Fully open lid is secured against falling off.
3.2
Getting connected
LVLØ switchboard houses all fuses, circuit breakers and
other protection units, powered by main or sub-main
distribution board of the building, used to distribute
electrical power to all swimming pool equipment.
3.2.1
Wire routing
LVLØ switchboard has a cable entry plate at the bottom of the enclosure. Entry plate is designed for routing
up to 24 standard cables (without connectors). Simply put a small slit in the thin membrane, push standard
cables through and it is immediately IP64 sealed (certified according to DIN EN 60529:2000-09).
Number of cables:
16× max. 6.5 mm
4× max. 12.1 mm
4× max. 16.1 mm
2× ASI cables