3.10.8
Redox/ORP and CLF Electrode settings
Electrodes configuration has to be performed via LVLØ mobile application in Service section; select Water
treatment.
ORP electrode: <installed/not installed> select if Redox (ORP) electrode is installed in the system.
CLF electrode: <installed/not installed> select if free chlorine electrode is installed in the system.
It is possible to have both ORP and CLF electrode; however CLF measurement has priority over the
ORP/Redox measurement in the dosing process.
3.10.9
Chemicals settings
3.10.9.1
pH minus, pH plus and chlorine
Chemicals settings setup of pH minus, pH plus and chlorine has to be performed via LVLØ mobile application
in Service section; select Water treatment. In this section you can define chemical barrel volume, see actual
barrel usage and volume left in barrel for each of the used chemicals.
<Chemicals> concentration: <value> value in ml/m3. Set chemicals dosage based on chemicals’ vendor
recommendations.
<Chemicals> barrel volume: <value> value in liters. Set volume of chemical barrel installed.
<Chemicals> barrel actual usage: Displays volume in liters that has been used from the installed volume.
<Chemicals> barrel left: Displays volume in liters left in the installed volume.
<Chemicals> barrel change: <button> Set barrel usage counters to zero and set barrel volume value as
countdown value.
<Chemicals> reset counter: <button> reset counter to initial values.
3.10.9.2
Algaecide and flocculants
Chemicals settings setup of algaecide and flocculants has to be performed via LVLØ mobile application in
Service section; select Water treatment.
<Chemicals> barrel volume: <value> value in liters. Set volume of chemical barrel installed.
<Chemicals> barrel actual usage: Displays volume in liters that has been used from the installed volume.
<Chemicals> barrel left: Displays volume in liters left in the installed volume.
<Chemicals> barrel change: <button> Set barrel usage counters to zero and set barrel volume value as
countdown value.
<Chemicals> reset counter: <button> reset counter to initial values.
<Chemicals> initial volume: <button> perform dosing of selected chemical in volume that is defined as initial
volume. Please note that filtration must be running to enable dosing of any chemicals.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to
system.
3.10.9.3
Stocks alert threshold
Chemical stocks alert threshold setup has to be performed via LVLØ mobile application in Service section;
select Water treatment.
Stocks alert threshold: <value> value in days. Define number of days in which the LVLØ system will start
warning before chemicals will need to be replaced.