SERVICE MANUAL
© ISA, s.r.o. 2014-2015. All rights reserved.
We reserve the right to change the specification without prior notification.
Always check for new version of this document@
Service manual V1.08 | Nov-2015 | LM0002-EN
Page 11 of 97
2.2.2
LVLØ Controller – connector board layout
13
Setting buttons
For movement in settings menu
14
rSMA connector
2.4GHz Wi-Fi antenna
15
BNC connector
ORP electrode
16
BNC connector
pH electrode
17
Air switch
AUX1 (attraction No. 1)
18
Air switch
AUX2 (attraction No. 2)
No. Connector
Description
1
Water temperature
sensor
3pin
1-wire sensor (included)
2
Outside temperature
sensor
3pin
1-wire sensor
3
Ext. heating
temperature sensor
3pin
1-wire sensor (included)
4
Pool cover
4pin
Max 5A @ 230V AC, 50/60Hz
5
Dosing pump 1-2
4pin
Max 1,3A @ 230V AC, 50/60Hz
pump 1 - pH minus, pump 2 - chlorine or algaecide
6
Dosing pump 3-4
4pin
Max 1,3A @ 230V AC, 50/60Hz
pump 3 - flocculants, pump 4 - pH plus
7
Aux 2 (attraction 2)
5pin
9-14A selectable @ 400/415V AC, 50/60Hz
8
Aux 1 (attraction 1)
5pin
6-10A selectable @ 400/415V AC, 50/60Hz
9
Light
2pin
Max 6A @ 230V AC, 50/60Hz
10
Filtration
5pin
1,6-2,5A @ 230/400/415V AC, 50/60Hz, clickable 1-phase or 3-
phase pump
11
Filtration setup
10pin Passive clamp selector for 1-phase or 3-phase pump
12
Free chlorine sensor
3pin
4-20mA Analog input
13
3-way valve
3pin
Max 2A @ 230V AC, 50/60Hz
14
BUS
2pin
LVLØ proprietary bus
15
Power 5V
2pin
Max 3A @ 5V DC