Sensor Wiring
Modline 5
67
Wire Pair
color coded
Wire Length
inches (mm)
YEL & YEL/WHT
3.0 (76)
BLU & BLU/WHT
2.2 (56)
ORG & ORG/WHT
1.4 (36)
VIO & VIO/WHT
2.2 (56)
BLK & BLK/WHT
3.0 (76)
RED & RED/WHT
10.0 (254)
Table: 14
D. Select Next Step. If the preparation is for a POI Box, see the separate POI manual for cable
preparation and installation instructions. If the preparation is for a Terminal Strip Plate, pull back
and comb out the exposed shield. Preparation is now complete. Route and install the
interconnecting cable. Refer to Section 4.6
Terminal Strip Plate – Sensor Interconnecting Cable
4.5.2
Interconnecting Cable Assembly Continuity Check
If desired, a continuity check of the cable can be made. The table below identifies the receptacle pin and
the color coded wire connected to the pin.
The illustration below identifies the pin locations on
the cable plug end.
Pin 1
Black/White
Pin 2
Red
Pin 3
Black
Pin 4
Violet
Pin 5
Blue
Pin 6
Yellow/White
Pin 7
Blue/White
Pin 8
Red/White and Violet/White
Pin 9
Orange
Pin 10 Yellow
Pin 11 Orange/White
Figure 58
Cable Shield is connected to the plug shell.
Red Dot Up