Goodrive10 Series Mini VFD
Communication protocol
-96-
Function instruction
Address
definition
Data meaning instruction
R/W
characteristics
(unit: 0.01V)
Analog input 2
300DH
0.00
–10.00V
(unit: 0.01V)
R
Reserved
300EH
R
Reserved
300FH
R
Reserved
3011H
R
Current step of the
multi-step speed
3012H
0
–15
R
Reserved
3013H
R
External count value
3014H
0
–65535
R
Torque setting
3015H
-300.0
–300.0%
(unit: 0.1%)
R
VFD identification
code
3016H
R
Fault code
5000H
R
The Read/Write (R/W) characteristics indicate whether a function can be read and written.
For example, "Communication-based control command" can be written, and therefore the
command code 6H is used to control the VFD. The R characteristic indicates that a function
can only be read, and W indicates that a function can only be written.
Note:
Some parameters in the preceding table are valid only after they are enabled. Take
the running and stop operations as examples, you need to set "Running command channel"
(P00.01) to "Communication", and set "Communication running command channel" (P00.02)
to the Modbus communication channel. For another example, when modifying "PID setting",
you need to set "PID reference source" (P09.00) to Modbus communication.
The following table describes the encoding rules of device codes (corresponding to the
identification code 2103H of the VFD).
8 MSBs
Meaning
8 LSBs
Meaning
0x01
GD
0x08
GD35 vector VFD
0x09
GD35-H1 vector VFD
0x0a
GD300 vector VFD
0x0b
GD100 simple vector VFD
0x0c
GD200 general VFD
0x0d
GD10 mini VFD
Note:
The code is consisted of 16 bit which is 8 MSBs and 8 LSBs. 8 MSBs indicate the
motor type series and 8 LSBs indicate the derived motor types of the series.