CHV180 series frequency inverter special for elevator Detailed function description
.51.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P5.00
Terminal input
mode selection
0~0x3FF
0~0x3FF
0
The function is to select the switch signal input terminals to be natural open or natural
close. It means terminal input is natural close when the corresponding bit is 1; the
parameter is 16 hex setting. Switch signal corresponding bit is as follows:
BIT9
BIT8
BIT7
BIT6
BIT5
S10
S9
S8
S7
S6
BIT4
BIT3
BIT2
BIT1
BIT0
S5
S4
S3
S2
S1
Function
Code
Name
Description
Setting
Range
Factory
Setting
P5.01
Terminal
function input
selection
0: Invalid
1: Valid
0~1
0
The function code is used to set the input channel of the terminal.
0: Communication virtual terminal invalid. The ON-OFF signal is input through the
external terminals.
1: Communication virtual terminal valid. The ON-OFF signal is set by the upper PC
through serial communication.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P5.02
S1 Terminal
function
Programmable
multifunction
terminal
0~55
1
P5.03
S2 Terminal
function
Programmable
multifunction
terminal
0~55
2
P5.04
S3 Terminal
function
Programmable
multifunction
terminal
0~40
8
P5.05
S4 Terminal
function
Programmable
multifunction
terminal
0~40
9
P5.06
S5 Terminal
function
Programmable
multifunction
terminal
0~40
3
P5.07
S6 Terminal
Programmable
multifunction
0~40
0