CHV180 series frequency inverter special for elevator Appendix D
.147.
Function
Code
Name
Description
Factory
Setting
Mod
ify
LCD Display
P7.17
Output current at
current fault
●
FAULT CURR
P7.18
DC bus voltage at
current fault
●
FAULT DC
VOLT
P7.19
Input terminal state at
current fault
●
FAULT Sx
STATE
P7.20
Output terminal state
at current fault
●
FAULT DO
STATE
P7.21~
P7.22
Reserved
0~65535
0
◎
RESERVE
P8 Group: Enhanced function
P8.00
Analog weigh signal
input selection
0: No function
1: AI1
2: AI2
0
◎
ANALOG
WEIGH
INPUT
P8.01
Pre-torque offset
0.0~100.0%
30.0%
○
PREP
TORQUE
OFFSET
P8.02
Drive side gain
0.000~7.000
1.000
○
DRIVE
PLUSE
P8.03
Brake side gain
0.000~7.000
1.000
○
BRAKE
PLUSE
P8.04
Brake, contactor
control selection(only
effective at terminals
control mode)
0: Invailble
1: Brake availble,
contactor invailble
2: Brake invailble,
contactor availble
3: Brake and contactor
availble
0
◎
BRAKE
CONTACTOR
CONTROL
P8.05
Close brake delay
time
0.00~5.00s
0
◎
CLOSE
BRAKE
DELAY
P8.06
Open brake delay 0.00~5.00s
0
◎
OPEN