CHV180 series frequency inverter special for elevator Detailed function description
.32.
input and current input is controlled by the jumper wire J18.
Note:
100% of AI is corresponding to the rated speed of the elevator.
3: Multi-step speed
The reference frequency is determined by P1 group and P5 group. The selection of
steps is determined by combination of multi-step speed terminals.
Note:
Multi-step speed mode will enjoy priority in setting reference frequency if
P0.03 is not set to be 3. In this case, only step 1 to step 7 are available.
If P0.03 is set to be 3, step 0 to step 7 can be realized.
4: Communication
The reference frequency is set through RS485. For details, please refer to chapter 11.
5: Al1 tracking running
Running s-curve when is decided by external controller, and internal acceleration and
deceleration is invalid.
Note:
When P0.03 is set to be 5, the process of acceleration and deceleration is
decided by external controller, the inverter tracks the change process of
analog automaticly.P0.03 is set to be 1 or 2, the process of acceleration
and deceleration is decided by internal controller.
Speed command and analog weighing signal input can’t select the same
analog input channel.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P0.04
Maximum
frequency
10~400.00Hz
10.0~400.00 50.00Hz
Note:
The frequency reference should not exceed maximum frequency.
Actual acceleration time and deceleration time are determined by maximum
frequency.