CHV180 series frequency inverter special for elevator Detailed function description
.75.
Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.03
Communication
reponse delay
0~20ms
0~20
0ms
Reply delay: refers to the interval time between the end of data receiving of the inverter
and the reply data sending of the upper computer. If the reply delay time is less than
the system processing time, take the system processing time as reply delay reference.
If the reply delay is longer than the system processing time, after data processing, the
system has to wait until the reply delay time is reached before sending data to the
upper computer.
Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.04
Communication
timeout fault
0.0~100.0s
0.0~100.0
0.0s
If the functional code is set to 0.0s, the communication delay time parameter is
disabled.
When the functional code is set to be a valid value, if the interval between the current
communication and the next communication exceeds the communication delay time,
the system will send a communication fault error (Err18).
Normally, it is set to be “disabled”. If this parameter is set in a consecutive
communication system, communication state can be monitored.
Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.05
Communication
reply enabled
selection
0~1
0~1
0
0: communication reply enabled
1: communication reply disabled
Selecting whether replying or not to master command.
Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.06
Reserved
1~127
1~127
1
PA.07
Reserved
0~6
0~6
4