CHV180 series frequency inverter special for elevator Detailed function description
.37.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P1.03
Multi-step
speed 3
0.000~P0.02
0.000~P0.02 0.000m/s
P1.04
Multi-step
speed 4
0.000~P0.02
0.000~P0.02 0.000m/s
P1.05
Multi-step
speed 5
0.000~P0.02
0.000~P0.02 0.000m/s
P1.06
Multi-step
speed 6
0.000~P0.02
0.000~P0.02 0.000m/s
P1.07
Multi-step
speed 7
0.000~P0.02
0.000~P0.02 0.000m/s
Multi-step speed is defined by P1.00~P1.07. The 8-step speed will be come ture by the
combination of 3 multi-step speed terminals. The detailed description is as follow:
Multi-step speed
terminal 3
Multi-step speed
terminal 2
Multi-step speed
terminal 1
Speed Setting
Function
code
OFF
OFF
OFF
Multi-step speed 0 P1.00
OFF
OFF
ON
Multi-step speed 1 P1.01
OFF
ON
OFF
Multi-step speed 2 P1.02
OFF
ON
ON
Multi-step speed 3 P1.03
ON
OFF
OFF
Multi-step speed 4 P1.04
ON
OFF
ON
Multi-step speed 5 P1.05
ON
ON
OFF
Multi-step speed 6 P1.06
ON
ON
ON
Multi-step speed 7 P1.07
Function
Code
Name
Description
Setting
Range
Factory
Setting
P1.08
Start quadric
acceleration
0.001~10.000
0.001~10.000 0.350m/s
P
3
P
P1.09
Start
acceleration
0.001~10.000
0.001~10.000 0.700m/s
P
2
P
P1.10
Speed-down
quadric
deceleration
0.001~10.000
0.001~10.000 0.350m/s
P
3
P