CHV180 series frequency inverter special for elevator Appendix D
.132.
Function
Code
Name
Description
Factory
Setting
Mod
ify
LCD Display
speed
SPEED
P0.06
Running direction
selection
0: Forward
1: Reverse
2: Forbid reverse
0
◎
RUN
DIRECTION
P0.07
Carrier frequency 1.0~16.0kHz
Depend on
model
○
CARRIER
FREQ
P0.08
Motor parameters
autotuning
0: No action
1: Rotation autotuning
2: Static autotuning
0
◎
AUTOTUNIN
G
P0.09
Restore parameters
0: No action
1: Restore factory
setting
2: Clear fault records
3:Restore parameters
for injection molding
machine
0
◎
RESTORE
PARA
P0.10
~P0.11
Reserved
0~65536
0
◎
RESERVE
P1 Group: Speed curve
P1.00
Multi-step speed 0 0.000~P0.02
0.000m/s
○
MULTI-STEP
SPEED 0
P1.01
Multi-step speed 1 0.000~P0.02
0.000m/s
◎
MULTI-STEP
SPEED 1
P1.02
Multi-step speed 2 0.000~P0.02
0.000m/s
◎
MULTI-STEP
SPEED 2
P1.03
Multi-step speed 3 0.000~P0.02
0.000m/s
◎
MULTI-STEP
SPEED 3
P1.04
Multi-step speed 4 0.000~P0.02
0.000m/s
◎
MULTI-STEP
SPEED 4
P1.05
Multi-step speed 5 0.000~P0.02
0.000m/s
◎
MULTI-STEP
SPEED 5
P1.06
Multi-step speed 6 0.000~P0.02
0.000m/s
◎
MULTI-STEP