CHV180 series frequency inverter special for elevator Communication protocol
.101.
The data address of control and state parameters please refer to the following table.
Parameter Description
Address
Meaning of value
R/W
Feature
Control command
1000H
0001H: Up running
W/R
0002H: Down running
0003H: Up running overhaul
0004H: Down running overhaul
0005H: Stop
0006H: Coast to stop
0007H: Reset fault
0008H: overhauling ceased
Inverter state
1001H
0001H: Up running
R
0002H: Down running
0003H: Standby
0004H: Fault
Communication setting
2000H
Communication Setting Range
(-10000~10000)
Note: the communication setting
is the percentage of the relative
value (-100.00%~100.00%). If
it is set as frequency source, the
value is the percentage of the
maximum frequency (P0.04).
W/R
Virtual terminal input
function setting
2001H
Reserved
W/R
State parameters
3000H
Output speed
R
3001H
Reference speed
R
3002H
DC Bus voltage
R
3003H
Output voltage
R
3004H
Output current
R
3005H
Running frequency
R
3006H
Rotation speed
R
3007H
Output power
R
3008H
Output torque
R