The yellow LED continues to blink slowly.
3.
To disable this feature, press:
30 # 0 # 0 # **
The yellow LED continues to blink slowly.
4.
Press * to exit Program mode.
4.4.5 Error Lockout
The prox.pad plus controller maintains a count of the
number of consecutive invalid keypad PINs and prox
cards that have been entered. This count is reset by
entering a valid keypad PIN, presenting a pro-
grammed prox card, pressing the program button, en-
tering a valid [99 # Master code*] sequence, or by the
expiration of the keypad timer.
Entering an incorrect Master code in a [99 # Master
Code*] sequence does increment the invalid PIN entry
count. This ensures that attempts to guess the Master
code are not overlooked.
When the invalid entry counter reaches the user-speci-
fied level, the error lockout is activated. Error threshold
is programmed through parameter 32 # 0 #, and is
defaulted to three attempts.
Once the error lockout threshold is reached, the key-
pad is locked out and the yellow LED lights solidly.
This duration defaults to 10 seconds, and is changed
with command 32, parameter 1.
Chapter 4: Programming
4.4 Programming Keypad Options and Parameters
4-26
prox.pad plus Install/Program. Manual, PPP, D2