When either the Master or Supervisor is pro-
grammed as “card AND code,” both are required
to enter Program mode.
•
When they are programmed for “card OR code,”
only the card is required to enter Program mode.
•
If the Master or Supervisor is programmed for
“card OR code” and you want them to require
both to enter Program mode, enable option 3 using
command 30 (30 # 3 # 1 # * *).
4.1.1.D prox.pad plus Default Settings
Table 4-1 lists the default settings for the prox.pad plus
unit as shipped from the factory. Subsequent sections
in this chapter explain how to change these default
settings or program additional functions.
Table 4-1. prox.pad plus Default Settings
Parameter
Default Setting
Main Relay
Lock Output
Auxiliary Relay
Alarm shunt function
Audio Alert #1
Forced Door
Audio Alert #2
Propped Door
Master Code (user one)
1234*
Main Relay energizes for
Five (5) seconds
Audible Keypress Feedback
ON
Propped Door Output activates after
Thirty (30) seconds
Forced Door Output activates for
Ten (10) seconds
4.1 Programming Overview
Chapter 4: Programming
prox.pad plus Install/Program. Manual, PPP, D2
4-3