3.
Press
*
to exit Program mode. The 70 command
is logged in the transaction buffer (in memory),
providing a reference as to when the log was
printed. Refer to the DCD software instructions
for details.
4.5.2.C Erasing a Transaction Log
The Transaction Log should be erased from memory
after being printed to prevent conflicting logs.
To
erase the log, enter the following sequence:
99 # Master Code * 76 # 00000 # 00000 #
**
Then press
*
to exit Program mode.
4.5.2.D Printing a Programmed Users List
The Programmed Users List showing all user access
information can be printed to the optional PDA soft-
ware via the unit’s IR port. The Print Programmed
Users List command is 25.
The prox.pad plus unit can store up to 2,000 user IDs
in memory at one time. Each user ID can be a card, a
PIN code, or a combination card/PIN code. User data
is stored in numbered registers, with register one being
known as “user one,” register two “user two,” etc.
User data is stored in the available memory registers
automatically by the unit; you do not have to place
data in any particular order. You can store codes or
cards in the first five registers and skip some registers,
leaving them empty on purpose; you can then con-
tinue programming from registers that are out of se-
quence. This is an important concept since the printed
list identifies the memory register (location) for each
user’s data. It does not print user locations that are not
programmed.
Chapter 4: Programming
4.5 Using the Printing Features
4-32
prox.pad plus Install/Program. Manual, PPP, D2