Action
Press
Details
24. Set/clear event
log mask
73 # event # set/clear # **
See options below;
all events are
logged by default
unless stated
otherwise below
Event
1
access denied - invalid PIN
2
program denied
4
REX
5
Propped Door
6
Door Closed
7
Forced Door
16
log dumped by user #N
17
access granted to user #N
19
access denied to user #N, bad
timezone
20
toggle mode activated by user #N
(latch set)
21
toggle mode de-activated by user
#N (latch clear)
22
1st in auto-unlock triggered by
user #N
23
door relocked by user #N
24
user lockout enabled by user #N
25
user lockout disabled by user #N
26
access denied to user #N - user is
disabled
27
card/code mismatch
29
program mode started by user #N
30
log erased by user #N
32
unprogrammed card data
33
unprogrammed code data
50
log retrieved
51
access denied to user #N, user
group lockout
Events 30 and 50
cannot be disabled
Events 32 and 33
are disabled by
default
25. Reset (erase)
transaction log
76 # 00000 # 00000 # **
26. To exit Program
mode
*
(after final command)
Yellow stops flashing
Chapter 4: Programming
4.6 Programming Commands
4-40