Chapter 2: Installation
34
FlexZone™ Product Guide
10. Insert the center conductors into opposing terminals on the splice circuit card
assembly (CCA) and tighten the screws. Insert the twisted braided shields
into the adjacent opposing terminals on the splice CCA, and tighten the
screws.
11. Secure both sensor cables to the splice CCA using the supplied cable ties.
Ensure that the heads of the cable ties are all on the same side of the CCA
and that they are at a 45º angle from the flat plane of the CCA.
Figure 38: Sensor cable splices steps 10 & 11
12. Line up the splice CCA so it is centered between the dual cable guide bars,
and press the assembly firmly into the gel snap enclosure. Press the sensor
cable into the cable guide bars. DO NOT remove the protective gel inside the
enclosure.
13. Snap the enclosure shut ensuring that both tabs are securely locked in the
slots.
Note:
The weather-proofing protective gel should be oozing out of the gel
snap enclosure.
Figure 39: Sensor cable splices steps 12 & 13
14. Form two 15 cm drip loops and attach the splice enclosure to the fence.
Insert the center conductors into opposing
terminals and tighten the screws
Insert the twisted braided shields into opposing
terminals and tighten the screws
45º
dual cable guide bars
dual cable guide bars
center the splice CCA between the dual cable guide bars
locking tabs in slots
Содержание FlexZone Series
Страница 1: ...FlexZone Product Guide P N 466 2877 REV C ISS 19MAR19...
Страница 6: ......
Страница 23: ...Chapter 1 System planning FlexZone Product Guide 17 Figure 11 High security redundancy 2 1 km example...
Страница 24: ......
Страница 41: ...Chapter 2 Installation FlexZone Product Guide 35 Figure 40 Mounting the splice enclosure 15 cm...
Страница 61: ...Chapter 2 Installation FlexZone Product Guide 55 Figure 63 UltraWave connection diagrams Silver Network Relay...
Страница 62: ......
Страница 86: ......
Страница 94: ......