Chapter 2: Installation
40
FlexZone™ Product Guide
Figure 47: Gate disconnect assembly
Installation instructions
1. Place the male cap stay wire over the open end of the non-detecting cable on
the male connector. Put the cap in place on the connector during installation.
2. Wrap a gear clamp (customer supplied) around the fixed post on the opening
side of the fence on which the gate disconnect will be mounted.
3. Before tightening the clamp, position the L-bracket against the post under the
clamp.
4. Tighten the clamp until the assembly is firmly attached to the post.
5. Dress the non-detecting cables to the splice kits with cable ties.
6. Follow the directions for a standard splice.
7. Attach the rubber cover over the disconnect assembly.
Note:
When caps are not in use, they fit into one another for protection and
storage. Cap the connectors when the gate will be open for extended periods.
Installing the FlexZone processor
Do not remove the processor circuit card when installing the enclosure. The
processor is shipped with two gear clamps that are used for securing the
enclosure to a post. The hardware required to mount the enclosure on another
type of surface is customer supplied. Figure 50 on page 43 shows a fence
cable tie
female disconnect
female cap
splice kit (X 2)
male disconnect
male cap
cable tie
gear clamp
gear clamp
bracket
disconnect
assembly
protective rubber cover
Содержание FlexZone Series
Страница 1: ...FlexZone Product Guide P N 466 2877 REV C ISS 19MAR19...
Страница 6: ......
Страница 23: ...Chapter 1 System planning FlexZone Product Guide 17 Figure 11 High security redundancy 2 1 km example...
Страница 24: ......
Страница 41: ...Chapter 2 Installation FlexZone Product Guide 35 Figure 40 Mounting the splice enclosure 15 cm...
Страница 61: ...Chapter 2 Installation FlexZone Product Guide 55 Figure 63 UltraWave connection diagrams Silver Network Relay...
Страница 62: ......
Страница 86: ......
Страница 94: ......