Chapter 2: Installation
FlexZone™ Product Guide
37
Figure 43: Sensor cable terminations steps 11 & 12
13. Attach the enclosure to the fence. Form a 20 cm drip loop and install the
enclosure horizontally to protect the cable entry points from rain and run off.
Figure 44: Mounting the termination enclosure
Installing sensor cable on gates
This section provides details about protecting swinging gates with FlexZone
sensor cable.
Gates usually require the same level of protection as the fence.
• Install the sensor cable on the side of the fence into which the gate panel
opens.
• If the gate panel opens in the opposite direction, or both directions, leave
enough slack in the sensor cable so that the gate can be fully opened in
either direction.
• Make sure that there is no loose sensor cable when the gate is closed.
• Run the cable from the fence to the gate at the hinged side of the gate, and
then back to the fence on the same side.
• Ensure that the cable cannot be caught and pinched when the gate opens
and closes.
• Run the cable once completely around the gate in a diamond pattern, app. 30
cm from the edge (respect the minimum bend radius - no sharp corners).
dual cable guide bars
dual cable guide bars
center the terminator CCA between the dual cable guide bars
locking tabs in slots
20 cm
Содержание FlexZone Series
Страница 1: ...FlexZone Product Guide P N 466 2877 REV C ISS 19MAR19...
Страница 6: ......
Страница 23: ...Chapter 1 System planning FlexZone Product Guide 17 Figure 11 High security redundancy 2 1 km example...
Страница 24: ......
Страница 41: ...Chapter 2 Installation FlexZone Product Guide 35 Figure 40 Mounting the splice enclosure 15 cm...
Страница 61: ...Chapter 2 Installation FlexZone Product Guide 55 Figure 63 UltraWave connection diagrams Silver Network Relay...
Страница 62: ......
Страница 86: ......
Страница 94: ......