Chapter 3: Calibration and setup
FlexZone™ Product Guide
63
Figure 65: FlexZone network connections
Sensor cable supervision
You must specify the sensor cable supervision method for each connected
FlexZone sensor cable. Several other functions depend on this setting
including power and data distribution over the sensor cables as well as
auxiliary power output.
1. Select the Side A Cfig tab.
2. In the Cable Side Configuration field, select the Cable Supervision Mode for
the Side A cable:
Figure 66: FlexZone sensor cable supervision
3. Repeat for the Side B cable.
4. Save and download the configuration changes to the processor.
Adjacent Processor (m) setting
If the selected cable side is connected to another processor via the sensor
cables, you must specify the total length of sensor cable between the 2
processors:
1. Select the Side A Cfig tab.
2. Select the total length of the 2 connected sensor cables from the Adjacent
Processor (m) drop down menu:
Figure 67: FlexZone sensor cable supervision
3. Repeat for the Side B cable (if necessary).
4. Save and download the configuration changes to the processor.
422/FO(A)<>Coax(B)
Coax + 422/FO
Coax(A)<>422/FO(B)
Coax
422/FO
Coax(A)<>Ethernet Ethernet<>Coax(B)
synchronization signal (out A in B)
network communication data flow
EOL resistor supervision
Cable pair/loop supervision
(enables power over sensor cables function)
specify the length of cable between the 2 processors
Содержание FlexZone Series
Страница 1: ...FlexZone Product Guide P N 466 2877 REV C ISS 19MAR19...
Страница 6: ......
Страница 23: ...Chapter 1 System planning FlexZone Product Guide 17 Figure 11 High security redundancy 2 1 km example...
Страница 24: ......
Страница 41: ...Chapter 2 Installation FlexZone Product Guide 35 Figure 40 Mounting the splice enclosure 15 cm...
Страница 61: ...Chapter 2 Installation FlexZone Product Guide 55 Figure 63 UltraWave connection diagrams Silver Network Relay...
Страница 62: ......
Страница 86: ......
Страница 94: ......