Chapter 2: Installation
FlexZone™ Product Guide
39
2. Make a service loop that reaches the gate without binding the cable when the
gate is fully opened in either direction.
3. Run the sensor cable around the perimeter of the gate panel in a diamond
pattern, app. 30 cm in from the edges. (For a double panel swinging gate
install the sensor cable on both gate panels.)
4. Pull the sensor cable through the buried conduit.
5. Seal the ends of the conduit.
6. Use cable ties to tightly secure any exposed bypass cable to the fence fabric.
7. Continue installing the sensor cable on the fence beyond the gate. (For a
double panel swinging gate install the sensor cable on the second gate panel
before continuing the cable run.)
Figure 46: Installing sensor cable on swinging gates
Gate disconnect assembly
Note:
The gate disconnect assembly can be used only with sensor cables that
are not carrying power and data to other FlexZone processors. Otherwise, using
the gate disconnect will interrupt power and data to any processor further down
the line.
The gate disconnect assembly protects gates that are infrequently used. The
gate can be opened and closed by manually separating the connection (see
Figure 47 below). When the assembly is opened, a supervision alarm is
generated. When the assembly is closed the gate is protected.
sensor cable
protected gates
bypass cable
Содержание FlexZone Series
Страница 1: ...FlexZone Product Guide P N 466 2877 REV C ISS 19MAR19...
Страница 6: ......
Страница 23: ...Chapter 1 System planning FlexZone Product Guide 17 Figure 11 High security redundancy 2 1 km example...
Страница 24: ......
Страница 41: ...Chapter 2 Installation FlexZone Product Guide 35 Figure 40 Mounting the splice enclosure 15 cm...
Страница 61: ...Chapter 2 Installation FlexZone Product Guide 55 Figure 63 UltraWave connection diagrams Silver Network Relay...
Страница 62: ......
Страница 86: ......
Страница 94: ......