Chapter 3: System functions
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
99
Event type details are listed in Table 20 below.
Table 20: Camera events and reporting codes
Event type
Activated by zone type [1]
SIA code [2]
Burglar alarm
1. Alarm, 2. Entry/Exit 1, 3. Access, 6. 24H, 13. Fire door,
BA
Fire alarm
FA
Panic alarm
PA
Medical alarm
MA
Tamper alarm
TA
Fault
11. Technical, 12. Transmission path fault, 14. Aux mains
UA
Custom type 1
Not allowed [3]
Selectable [4]
Custom type 2
Not allowed [3]
Selectable [4]
[1] Zones of particular types do not activate camera. These are 8. Exit terminator, 9. Keyswitch,
17. Eng. reset. When an assigned zone is one of the listed types, it is ignored when active.
[2] If the camera has been activated by a standard reporting event, another event caused by
camera activation does not occur. Detailed codes and subevent values are described in
Appendix B “Advisor Advanced reporting codes” on page 327.
[3] Custom type events can only be activated by condition filters.
[4] See “4.5.n.3.m.3 Report as” on page 194 for details.
Each of these types can be configured in “2.2.2.n.4.9.1 Pic settings” on page
155.
Depending on camera event type, the camera can be programmed to take a
single picture or a series of pictures, in low or high resolutions.
How to program a camera:
1. Program the wireless PIR camera expander. See “Bus devices” on page 58
for more details.
2. Program a wireless PIR camera as a wireless PIR detector. See “Wireless
device programming” on page 92 for more details.
If the detector is programmed successfully, the appropriate camera is created
automatically. The created camera number is equal to the zone number of the
wireless PIR detector.
3. Program the camera options. See “4.5 Cameras” on page 193.
4. Assign zones to the camera. Choose up to four zones. The camera is useful if
its field of view covers these zones or possible burglar escape paths from
there. See “4.5.n.2 Pics by zone” on page 193.
By default, the first assigned zone is the zone of the wireless detector built in
the configured wireless PIR camera.
5. If necessary, program conditional event filters that activate the camera. See
“4.5 Cameras” on page 193 for details.
Содержание ATS1500A-IP-LP
Страница 1: ...Advisor Advanced ATSx500A IP Installation and Programming Manual P N 466 2576 EN REV B ISS 16SEP16...
Страница 12: ...Chapter 1 Quick installation and programming 6 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 110: ...Chapter 3 System functions 104 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 332: ...Appendix A Advisor Advanced events 326 Advisor Advanced ATSx500A IP Installation and Programming Manual...