MEQ-2000
24/96 Multimode Equalizer
LIMITER MODE Screen
Pressing the
MODE
key accesses the
LIMITER MODE
screen, which allows for global setups
for the
LIMITER
module.
In this screen, parameters are selected with the
and
cursor keys and adjusted
with the parameter wheel. After every change,
ENTER
appears at the
F5
key, and must
be pressed to confirm the change. Default settings can be selected with the
F1
(
DEF
)
key. Pressing the
F6
(
EXIT
) key returns to the
LIMITER
screen.
Global parameters available in the
COM/LIM MODE
screen are:
CH LINK
determines the channel coupling status:
OFF
selects dual channel mode, with two independent channels.
CH1
→
2
couples the channels with
CH1
slaved to
CH2
.
CH2
→
1
couples the channels with
CH2
slaved to
CH1
.
ST COUPL
couples the limiter in both channels to avoid stereo image jumping.
CEILING
links the threshold (
THR
) and output gain (
GAIN
) parameters so that the
LIMITER
output remains at the same level independent of the
THR
value.
Useful for finding the maximum degree of compression at a given output
level.
LA DELAY
selects a look-ahead delay time. Available delay times are: 0.2, 0.3, 0.5, 1,
2, 3, 5 or 10 ms. Longer delay times are recommended in most
circumstances for cleaner results when applying heavy compression to
low-frequency signals.
Default values are
CH1
→
2, OFF, OFF, 2 ms.
30
Содержание MEQ-2000
Страница 1: ...MEQ 2000 24 96 Multimode Equalizer Copyright 2004 Inter M Corporation...
Страница 4: ...MEQ 2000 24 96 Multimode Equalizer 4...
Страница 12: ...MEQ 2000 24 96 Multimode Equalizer OVERVIEW Signal Flow Diagram 12...
Страница 42: ...MEQ 2000 24 96 Multimode Equalizer Typical Digital Interconnections 42...
Страница 49: ...MEQ 2000 24 96 Multimode Equalizer UTILITY MENU STRUCTURE 49...
Страница 56: ...MEQ 2000 24 96 Multimode Equalizer Block Diagram 56...