The screen below displays the second set of parameters available:
ATT
adjusts the attack time over a range of 0.1 ms to 20 ms in 0.1 ms
increments.
REL
adjusts the release time over a range of 10ms to 5000 ms in 10 ms
increments.
HOLD
adjusts the hold threshold below
THR
, over a range of 0 to 3dB in 0.1 dB
increments.
ART
selects the mode of the Automatic Release Time algorithm. Available
options are:
OFF, LAZY, NORM
, and
QUICK
. Use
QUICK
for program
material high in dynamics; use
LAZY
for slow instrumental and symphonic
music.
The
COM/LIM
module utilizes a “look-ahead” algorithm that allows a highly reliable
limiting function. To help configure the compressor/limiter for optimal performance, the
COM/LIM
screen provides input and output level meters, a limiter characteristic display,
and a gain reduction meter. For best performance and minimal distortion, the gain
reduction meter should normally not exceed –12dB. If the output gain is at maximum and
the
OVF
flag is flashing, decrease the gain slightly to avoid clipping. You can also
activate the
SOFT CLIP
function in the
LEVELS
module (
MODE
menu).
27
Содержание MEQ-2000
Страница 1: ...MEQ 2000 24 96 Multimode Equalizer Copyright 2004 Inter M Corporation...
Страница 4: ...MEQ 2000 24 96 Multimode Equalizer 4...
Страница 12: ...MEQ 2000 24 96 Multimode Equalizer OVERVIEW Signal Flow Diagram 12...
Страница 42: ...MEQ 2000 24 96 Multimode Equalizer Typical Digital Interconnections 42...
Страница 49: ...MEQ 2000 24 96 Multimode Equalizer UTILITY MENU STRUCTURE 49...
Страница 56: ...MEQ 2000 24 96 Multimode Equalizer Block Diagram 56...