Receiver Description
STEL-2176
20
User Manual
RECEIVE AND UNIVERSAL REGISTER DESCRIPTIONS
PROGRAMMING THE 2176 RECEIVE
FUNCTIONS
The STEL-2176 has a combination of universal, receive
and transmit registers. The registers are arranged as
three banks of registers (Bank 0, Bank 1, and Bank 2).
The Bank 0 registers are divided into Group 1 and
Group 2 registers. The Bank 1 and 2 registers form
separate groups (Groups 3 and 4 respectively). The
Bank 0 and 1 registers (Groups 1, 2, and 3) are
described by the following paragraphs. The Bank 2
registers (Group 4) are described in the Transmitter
section (see page 54).
The Bank/Group address, shown below, must be
written to register location FF
H
to access the respective
bank of registers. Register location FF
H
can be accessed
from each register bank/group. The registers can be
accessed using the Microcontroller Interface's parallel
or serial interface (see page 11).
REGISTER DESCRIPTIONS
Bank 0 - Universal Registers (Group 1)
The Universal Registers (Bank 0, Group 1) consist of
three sets of registers: Read/Write (see Table 6), Read-
only, and Write-only (see Table 7). The Read-only
register set (Bank 0 Register F2) is for factory use only
and not described by this User Manual.
Bank
Group
Group Name
Bank/Group Address
(location FF
H
)
0
1
Universal Registers (Group 1)
00
H
0
2
QAM Demodulator Registers Universal Registers (Group 2)
00
H
1
3
Downstream FEC Registers
01
H
2
4
Upstream, or transmitter, Registers
02
H
Table 6. Read/Write Register Set
Address
7
6
5
4
3
2
1
0
F1
H
Not Used
FECTestMode
(Bypass QAM)
Factory Use Only
Program to 0
H
F4
H
Not Used
BypassMPE
Gframe
(write only)
VitFeedBackEn
Factory Defined Value - 0
H
F5
H
Not Used
Factory Defined Value - 2
H
RxBypassFsyn
TxBypassFsyn
F6
H
Not Used
RxFsynM
F7
H
Not Used
RxFsynN
F8
H
Not Used
TxFsynM
F9
H
Not Used
TxFsynN
FA
H
Not Used
FB
H
Not Used
Factory Use Only
FD
H
QAMAcquisitionMaxTries
FE
H
Not Used
QAMEnable
QAMType
FEC Type
Table 7. Write Only Registers:
Address
7
6
5
4
3
2
1
0
F3
H
Not Used
Reset_OutputFIFO
Factory
Defined
Value - 0
H
FC
H
VitFeedBack
Factory Defined Value - 0
H
LoadRxM
LoadRxN
LoadTxM
LoadTxN
QAM Start