Intel® SRMK2 Internet Server Technical Product Specification
50
3.18 Jumper Blocks
Figure 18 shows the locations of the password override, BIOS Setup configuration and
whitebox/Appliance jumpers.
CAUTION
Do not move a jumper with the power on. Always turn off the power and unplug the power cord from the
computer before changing jumper settings.
A
B
C
A
B
C
BIOS Setup jumper
Whitebox / Appliance jumper
Clear Password jumper
Figure 18
:
BIOS Setup configuration and password override jumpers
The table below shows the jumper settings for the BIOS Setup jumper (J19). This jumper is
normally set with a jumper covering pins 1&2. BIOS recovery is performed by removing the
jumper (you need to have a BIOS diskette in the floppy disk drive) or you can enter the BIOS by
using the Configuration jumper setting by moving the jumper to pins 2&3.
Table 37: BIOS Setup jumper (J19)
Function /
Mode
Jumper Configuration
Normal
1-2
The BIOS uses current configuration information and passwords for booting.
Configure
2-3
After the POST runs, setup runs automatically. The Maintenance menu is displayed.
Recovery
None
The BIOS attempts to recover the BIOS configuration. A recovery diskette is required.
Содержание SRMK2 - Server Platform - 0 MB RAM
Страница 4: ...Intel SRMK2 Internet Server Technical Product Specification iv Blank Page Prevention words ...
Страница 12: ...Intel SRMK2 Internet Server Technical Product Specification 12 This page was intentionally left blank ...
Страница 56: ...Intel SRMK2 Internet Server Technical Product Specification 56 5 0 1 0 1 0 Figure 20 PCI riser board ...
Страница 115: ...Intel SRMK2 Internet Server Technical Product Specification 115 ...