Intel
®
Server System R2000WT Product Family System Integration and Service Guide
68
•
Locate the Left (with USB port) and Right (with control panel) storage rack handle assemblies from Intel
Accessory Kit A2UHANDLKIT
•
Lay each rack handle assembly near the left and right chassis corners and route the ribbon cables from
each rack handle along the inside of each chassis side wall towards the back of the drive bay
•
Attach the left and right rack handle assemblies to the chassis using three fastener screws each (8 in/lbs
torque for each screw). Note that the ribbon cables should fit inside cutouts in the chassis sidewall.
•
Attach the Left USB flat cable to the Black 10-pin server board connector labeled “FP_USB”
•
Attach the Right front panel ribbon cable to the White 30-pin connector labeled “Storage_FP” on the
front right corner of the server board
•
Ensure that the ribbon cables are routed within the cable channel inside each chassis sidewall, then
secure them using fastener tape strips
Install the 8 x 2.5” drive bay module(s)
Left Storage Front