Intel
®
Server System R2000WT Product Family System Integration and Service Guide
50
3.2
Power Supply Module – Installation / Removal
3.2.1
Power Supply Module Installation
Figure 63. Power Supply Module Installation
•
(If installed) Remove the insert from the chassis power supply bay
•
Insert the power supply module into the power supply bay
•
Push the power supply module into the bay until it locks into place
3.2.2
Power Supply Module Removal
Caution:
The power supply is only hot-swappable (system does not have to be powered down) if the system is
configured with two power supply modules operating in a 1+1 Redundant configuration only.
Systems with a single power supply installed or a system operating in a 2+0 non-redundant power mode,
MUST be powered OFF before removing the power supply module from the system.
•
Detach the power cord from the power supply to be removed
•
Using the handle, pull the power supply module from the system while pushing the green latch in the
direction shown
Figure 64. Power Supply Module Removal