Intel® Server System M70KLP Family Service Guide
59
5.
FRU Replacement
This chapter provides instructions for the replacement of system components considered to be field
replaceable (FRU). Only system features that are identified as hot-swappable can be replaced while the
system remains operational. These include:
•
Power Supply
–
Dual power supply 1+1 redundant configurations only
•
Drives mounted within the front drive bay
–
Fault Tolerant RAID (1, 5, 6, and 10) configurations only
•
System Fans
All other components within the system can only be serviced after the system has been powered off and AC
power cords have been disconnected from the server system.
All procedures documented in this chapter
include an “Average Time to Complete”
the procedure. The
service time is measured from the moment the system top cover is removed to the time the top cover is
reinstalled. Or for component replacement that does not require top cover removal, the time the component
is removed from the system to the time it is reinstalled.
Intel recommends that all system service procedures be performed by a qualified service technician.
Before You Begin
Before replacement of any system components, review all the safety and ESD precautions found in the
Safety Warnings section at the beginning of this document.
System Reference
In the following procedures, all references to left, right, front, top, and bottom assume the reader is facing
the front of the server chassis.
Instruction Format
Each procedure described in this chapter follows an illustration first format. This format gives the reader the
option to follow a quicker path to completing the objective by first seeing an illustration of the intended
procedural step or steps. If necessary, the reader can follow the step-by-step instructions that follow each
illustration.
Warranty Replacement Packaging
For warranty replaced components, save, and reuse all packaging the replacement component came in when
sending the failed component back to Intel.
Top Cover and Air Duct Removal / Installation
Most procedures documented in this chapter will require access to the inside of the system. If necessary,
instructions to remove and reinstall the system top cover and system air duct can be found in Chapter 2 of
this document.
Содержание M70KLP Series
Страница 2: ...Intel Server System M70KLP Family Service Guide Blank page...
Страница 94: ...Intel Server System M70KLP Family Service Guide 92 1 2 3 4 5 6 1 2 3...
Страница 95: ...Intel Server System M70KLP Family Service Guide 93 1 2 3 4 5...
Страница 96: ...Intel Server System M70KLP Family Service Guide 94 7 8 9 10 11 12 4 5 6...
Страница 97: ...Intel Server System M70KLP Family Service Guide 95 6 7 8 9 10...
Страница 106: ...Intel Server System M70KLP Family Service Guide 104 1 2 3 4 5 ESD 6 1 2 3...
Страница 107: ...Intel Server System M70KLP Family Service Guide 105 1 2 3 4 5...