Intel® Server System M70KLP Family Service Guide
63
7.
Align the notch at the bottom edge of the memory module with the key in the memory slot
(see Letter B).
8.
Insert the memory module into the memory slot.
•
Using even pressure along the top edge, push down on the memory module (see Letter C) until
the ejection tabs of the memory slot snap into place (see Letter D).
9.
Ensure that the ejection tabs are firmly in place (see Letter E).
10.
Reinstall the system air duct and top cover (see
Sections 2.2.1
Note:
Replacing
Intel® Optane™ PMem devices require
s additional steps to enable and configure them. Refer
to the appropriate Intel® Optane™ PMem d
ocumentation to complete the installation process for these
devices.
5.3
System Battery Replacement
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
CR-2032 Replacement Battery
Average Time to Complete:
~ 5 minutes
Procedure Prerequisites
•
The system must be powered off and AC power cord(s) disconnected.
•
Remove the system top cover and air duct ( See
Sections 2.2.1
•
(If present) Remove the riser card #0 assembly from the system (see
Section 3.2.3
Figure 79. System Battery Removal
1.
Locate the battery on the server board.
2.
Press the metal clip to release the battery (see Letter A).
3.
Remove the battery from its socket (see Letter B).
4.
Dispose of the battery according to local laws.
Содержание M70KLP Series
Страница 2: ...Intel Server System M70KLP Family Service Guide Blank page...
Страница 94: ...Intel Server System M70KLP Family Service Guide 92 1 2 3 4 5 6 1 2 3...
Страница 95: ...Intel Server System M70KLP Family Service Guide 93 1 2 3 4 5...
Страница 96: ...Intel Server System M70KLP Family Service Guide 94 7 8 9 10 11 12 4 5 6...
Страница 97: ...Intel Server System M70KLP Family Service Guide 95 6 7 8 9 10...
Страница 106: ...Intel Server System M70KLP Family Service Guide 104 1 2 3 4 5 ESD 6 1 2 3...
Страница 107: ...Intel Server System M70KLP Family Service Guide 105 1 2 3 4 5...