Intel® Server System M70KLP Family Service Guide
47
3.6
M.2 Storage Device Installation / Removal
On the system air duct is an M.2 SSD interface board that supports up to two SATA M.2 SSDs. Each
connector can support SSDs that conform to a 22110 (110 mm) or 2280 (80 mm) form factor.
Figure 56. M.2 SSD Interface Board
Required Tools and Supplies
•
Anti-static wrist strap and ESD safe workbench (recommended)
System Prerequisites
•
The system must be powered off and AC Power cord(s) disconnected
•
Remove the system top cover
–
See
Section 2.1
3.6.1
M.2 SSD Installation
Figure 57. M.2 SSD Installation
1.
Slide the M.2 SSD into the M.2 SSD slot (see Letter A).
2.
Ensure the notch at the end of the SSD is sitting over the shouldered edge of the lock pin stand-off.
3.
Insert the yellow fastener pin into the lock pin stand-off (see Letter B).
Note:
The lock pin stand-off can be repositioned to accommodate M.2 cards of various lengths.