Intel® Server System M50FCP1UR System Integration and Service Guide
87
6.12.2
12 X 2.5” Backplane Replacement
Required Tools and Supplies
•
Intel backplane kit
•
Anti-static wrist strap and conductive anti-static wrist strap and conductive workbench pad
(recommended)
•
Phillips* head screwdriver #1
Figure 120. 12 x 2.5” Backplane Removal
1.
Power off the system and disconnect the system power cords.
2.
Remove the system top cover (see
Section 6.1.1
3.
Remove all drives and drive blanks from the front drive bays. NOTE: If drives are configured to a RAID
partition, label the drives to identify the drive bay location they were removed from.
4.
Disconnect all cables from the backplane. NOTE: If drives are configured to a RAID partition, label
each drive I/O cable to identify the backplane cable connection they were disconnected from.
5.
Remove the seven screws securing the backplane to drive bay (see Letter A).
6.
Lift the backplane up from the chassis base and pull it out from the system (see Letter B).
Содержание M50FCP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Страница 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Страница 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Страница 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Страница 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Страница 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...