Intel® Server System M50FCP1UR System Integration and Service Guide
26
8.
Align Pin 1 indicator of processor carrier clip with the corner cut-out on the heat sink. For the EVAC
heat sink, align the processor carrier clip and the heat sink as shown in
Note:
In a standard heat sink there are two cut-out corners, either can be used to align Pin 1
indicators.
9.
Gently press down the heat sink onto the processor carrier clip until it clicks into place.
10.
Ensure that all four heat sink corners are securely latched to the tabs on the processor carrier clip.
2.3.2
Processor Installation
Caution:
Do not touch the socket pins. The pins inside the processor socket are extremely sensitive. A
damaged processor socket may produce unpredictable system errors.
Figure 17. Socket Protective Cover Removal
1.
(If present) Remove the processor socket cover by squeezing the finger grips (see Letter A) and
pulling the cover up from the processor socket (see Letter B).
Caution
: Ensure that the processor socket is free of damage or contamination before installing the PHM. If
debris is observed, blow it away gently with an air blower. Do not use tweezers or any other hard tools to
remove it manually.
Содержание M50FCP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Страница 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Страница 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Страница 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Страница 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Страница 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...