Intel® Server System M50FCP1UR System Integration and Service Guide
47
4.
Insert the RMFBU super capacitor into the plastic housing with the cable protruding out from one of
the cable routing openings. Choose the opening that results in the best cable routing to the RAID
module.
Figure 53. Intel® RMFBU Mounting Plate Installation
5.
If the system is powered on, power off the system and then disconnect the system power cords.
6.
Remove the system top cover (see
Section 3.1.1
7.
(If installed) Remove the cable clip by removing the two screws securing it to the chassis.
8.
Locate the RMFBU mounting plate.
9.
Align the two screw holes of the RMFBU mounting plate with the matching threaded holes on the
chassis base (see Letter A).
10.
Secure the RMFBU mounting plate to the chassis using two screws (see Letter B). Tighten to 5 in-lb.
11.
Slide the RMFBU housing assembly in the direction as indicated on the mounting plate (see Letter C)
until the latch locks in place.
12.
Attach cables as required.
13.
Reinstall the system top cover (see Section 3.1.2).
Содержание M50FCP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Страница 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Страница 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Страница 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Страница 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Страница 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...