Intel® Server System M50FCP1UR System Integration and Service Guide
106
Table 12. POST Error Messages and Handling
Error Code
Error Message
Action Message
Type
0012
System RTC date/time not set
Major
0048
Password check failed
Put right password.
Major
0140
PCI component encountered a PERR error
Major
0141
PCI resource conflict
Major
0146
PCI out of resources error
Enable Memory Mapped I/O above 4
GB item at SETUP to use 64-bit MMIO.
Major
0191
Processor core/thread count mismatch detected
Use identical CPU type.
Fatal
0192
Processor cache size mismatch detected
Use identical CPU type.
Fatal
0194
Processor family mismatch detected
Use identical CPU type.
Fatal
0195
Processor Intel(R) UPI link frequencies unable to
synchronize
Fatal
0196
Processor model mismatch detected
Use identical CPU type.
Fatal
0197
Processor frequencies unable to synchronize
Use identical CPU type.
Fatal
5220
BIOS Settings reset to default settings
Major
5221
Passwords cleared by jumper
Major
5224
Password clear jumper is Set
Recommend reminding user to install
BIOS password as BIOS admin
password is the primary keys for
several BIOS security features.
Major
8130
CPU 0 inactivated
Major
8131
CPU 1 inactivated
Major
8160
CPU 0 unable to apply microcode update
Major
8161
CPU 1 unable to apply microcode update
Major
8170
CPU 0 failed Self-Test (BIST)
Major
8171
CPU 1 failed Self-Test (BIST)
Major
8180
CPU 0 microcode update not found
Minor
8181
CPU 1 microcode update not found
Minor
8190
Watchdog timer failed on last boot.
Major
8198
OS boot watchdog timer failure.
Major
8300
Baseboard Management Controller failed self-test.
Major
8305
Hot Swap Controller failure
Major
83A0
Management Engine (ME) failed self-test.
Major
83A1
Management Engine (ME) Failed to respond.
Major
84F2
Baseboard management controller failed to respond
Major
84F3
Baseboard Management Controller in Update Mode.
Major
84F4
Baseboard Management Controller Sensor Data Record
empty.
Update right SDR.
Major
84FF
System Event Log full
Clear SEL through EWS or SELVIEW
utility.
Minor
85FC
Memory component could not be configured in the
selected RAS mode
Major
8501
Memory Population Error
Plug DIMM at right population.
Major
8502
PMem invalid DIMM population found on the system.
Populate valid POR PMem DIMM
population.
Major
8520
Memory failed test/initialization CPU0_DIMM_A1
Remove the inactivated DIMM.
Major
8521
Memory failed test/initialization CPU0_DIMM_A2
Remove the inactivated DIMM.
Major
8522
Memory failed test/initialization CPU0_DIMM_A3
Remove the inactivated DIMM.
Major
Содержание M50FCP1UR
Страница 2: ...2 This page intentionally left blank...
Страница 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Страница 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Страница 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Страница 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...
Страница 130: ...Intel Server System M50FCP1UR System Integration and Service Guide 130 1 2 3 4 5 ESD 6 1 2 3...
Страница 131: ...Intel Server System M50FCP1UR System Integration and Service Guide 131 1 2 3 4 5...