Intel® Server Board M50CYP2SB Family Technical Product Specification
145
Caution:
Processor socket pins are delicate and bend easily. Use extreme care when placing the PHM
onto the processor socket. Do not drop it.
Figure 82. PHM Installation onto Server Board
4.
Set all four anti-tilt wires on the heat sink to the inward position (see Letter A).
5.
Holding the PHM horizontally, carefully lower it on to the bolster plate’s alignment pins (see Letter
B).
6.
Set all four anti-tilt wires on the heat sink to the outward position (see Letter C).
Figure 83. Tighten Heat Sink Fasteners
7.
Tighten the heat sink fasteners using a T30 Torx* screwdriver to 8 in-lb. No specific sequence is needed
for tightening.
8.
Reinstall the air duct, if needed.
9.
Reinstall system top cover, if needed.
Important:
Do not install a processor heat sink on an empty socket. Also, only install a socket cover on an
empty socket