Intel® Server Board M50CYP2SB Family Technical Product Specification 

 

74 

 

 

7.2

 

PCIe* Riser Card Support 

The server board provides three riser card slots identified as: Riser Slot #1, Riser Slot #2, and Riser Slot #3. 
The PCIe* bus lanes for Riser Slot #1 are supported by CPU 0. The PCIe* bus lanes for Riser Slot #2 and Riser 
Slot #3 are supported by CPU 1.  

Note:

 The riser card slots are specifically designed to support riser cards only. Attempting to install a PCIe* 

add-in card directly into a riser card slot on the server board may damage the server board, the add-in card, 
or both. 

Note:

 A dual processor configuration is required when using Riser Slot #2 and Riser Slot #3. 

7.3

 

PCIe* Interposer Riser Slot (Intel® Server Board M50CYP2SB1U Only) 

The PCIe* Interposer Riser Slot and PCIe* interposer riser card provide additional add-in card support for the 
server system. The PCIe* interposer riser card shown in the following figure is an accessory option supported 
by the PCIe* Interposer Riser Slot.

 

This card has one PCIe* add-in card slot (x8 electrical, x8 mechanical) labeled 

Slot1_PCIe_x8

” 

that supports 

one low profile, half length, single-width add-in card.  

The PCIe* interposer riser card also has one x8 PCIe* NVMe* SlimSAS* connector labeled 

Slot1_PCIe_AIC_

Interposer”

 

Figure 43. PCIe* Interposer Riser Card 

Table 30. PCIe* Interposer Riser Card Connector Description 

Connector 

Description 

Slot1_PCIe_x8 

CPU 1 

 Ports 1A

1B 

(x8 electrical, x8 mechanical) 

PCIe* Interposer Cable 
Connector 

CPU 1 

 Ports 1A

1B 

(x8 electrical, x8 mechanical) 

 

Table 31. PCIe* Interposer Riser Slot Pinout 

Pin #

 

PCIe* Signal (from 

processor perspective) 

 

Pin # 

PCIe* Signal (from 

processor perspective) 

A1 

GND 

 

B1 

GND 

A2 

Spare 

 

B2 

Spare 

A3 

Spare 

 

B3 

Spare 

A4 

GND 

 

B4 

GND 

A5 

12V 

 

B5 

12V 

A6 

12V 

 

B6 

12V 

PCIe* Interposer Cable Connector 

Содержание M50CYP2SB Series

Страница 1: ...SB Family Technical Product Specification An overview of product features functions architecture and support specifications Rev 1 3 September 2021 Delivering Breakthrough Data Center System Innovation...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...el VROC for SATA Appendix H Updated Tables 56 and 57 Minor updates throughout for clarity September 2021 1 3 Table 1 Document References Added two DCM documents and the 3rd Generation Intel Xeon Scala...

Страница 4: ...ts or errors known as errata which may cause the product to deviate from published specifications Current characterized errata are available on request Intel disclaims all express and implied warranti...

Страница 5: ...ed Memory 39 4 2 1 Standard DDR4 DIMM Support 40 4 2 2 Intel Optane Persistent Memory 200 Series Module Support 41 4 3 Memory Population 43 4 3 1 DDR4 DIMM Population Rules 44 4 3 2 Intel Optane Persi...

Страница 6: ...imSAS Connector 68 7 PCI Express PCIe Support 73 7 1 PCIe Enumeration and Allocation 73 7 2 PCIe Riser Card Support 74 7 3 PCIe Interposer Riser Slot Intel Server Board M50CYP2SB1U Only 74 7 3 1 PCIe...

Страница 7: ...assword Rights 101 12 1 3 Authorized System User Password Rights and Restrictions 102 12 2 Front Panel Lockout 102 12 3 Intel Platform Firmware Resilience Intel PFR 102 12 4 Intel Total Memory Encrypt...

Страница 8: ...ily 148 I 2 Intel Server System M50CYP1UR Family 152 Appendix J Regulatory Information 156 Appendix K Glossary 158 List of Figures Figure 1 Intel Server Board M50CYP2SB Family 13 Figure 2 Intel Server...

Страница 9: ...sole Main Console View 56 Figure 32 MAIN PWR 1 and MAIN PWR 2 Connectors 59 Figure 33 Hot Swap Backplane Power Connector 61 Figure 34 Riser Slot Auxiliary Power Connectors 62 Figure 35 Peripheral Powe...

Страница 10: ...al from PHM Assembly 140 Figure 74 Processor Carrier Clip Removal from PHM Assembly 141 Figure 75 Installing Processor Carrier Clip onto Processor Part 1 141 Figure 76 Installing Processor Carrier Cli...

Страница 11: ...rd M50CYP2SBSTD and M50CYP2SB1U 67 Table 23 6 Pin Fan Pinout Intel Server Board M50CYP2SBSTD 68 Table 24 CPU 0 CPU 1 Fan Pinout 68 Table 25 PCIe SlimSAS Connector A Pinout CPU 0 and CPU 1 69 Table 26...

Страница 12: ...Error Beep Codes 126 Table 51 Integrated BMC Beep Codes 126 Table 52 Mixed Processor Configurations Error Summary 127 Table 53 Server Board Components 129 Table 54 Connectors and Headers 130 Table 55...

Страница 13: ...n Scalable processor families are not supported The Intel Server Board M50CYP2SB family is a foundational building block of the server system The family is backed by Intel design excellence manufactur...

Страница 14: ...50CYP and D40AMP Families Intel Confidential BIOS setup information on Intel Server M50CYP Family BIOS Setup Utility User Guide For the Intel Server Boards D50TNP M50CYP and D40AMP Families Public BMC...

Страница 15: ...e Utility User Guide To obtain full system information Intel SYSINFO Utility for Intel Server M50CYP Family Public Intel Server Information Utility User Guide To configure save and restore various sys...

Страница 16: ...TDP 3rd Gen Intel Xeon Scalable processors can operate up to 270 W server board only Note The maximum supported processor TDP at the system level may be lower than what the server board can support Su...

Страница 17: ...o 64 GB s Riser Slot 2 supports the following Intel Riser Card options Two PCIe slot riser card supporting one FH FL double width slot x16 electrical x16 mechanical one FH HL single width slot x16 ele...

Страница 18: ...t The port follows DTK pinout specifications Server Management Integrated Baseboard Management Controller BMC Intelligent Platform Management Interface IPMI 2 0 compliant Support for Intel Data Center...

Страница 19: ...ation 19 2 2 Server Board Component Feature Identification Figure 2 Intel Server Board M50CYP2SBSTD Component Feature Identification Note The features identified in the above figure represent their in...

Страница 20: ...res identified in the above figure represent their intended usage when the board is integrated into an Intel chassis The server board includes LEDs to identify system status and or indicate a componen...

Страница 21: ...Intel Server Board M50CYP2SB Family Technical Product Specification 21 Figure 4 Intel Light Guided Diagnostics LED Identification...

Страница 22: ...Intel Server Board M50CYP2SB Family Technical Product Specification 22 Figure 5 Fan fault LEDs on Intel Server Board M50CYP2SB1U Figure 6 Intel Light Guided Diagnostics DIMM Fault LEDs...

Страница 23: ...23 The server board includes several jumper headers see Figure 7 that can be used to configure protect or recover specific features of the server board For more information on reset and recovery jumpe...

Страница 24: ...mily Technical Product Specification 24 2 3 Server Board Dimensions The following figure shows the Intel Server Board M50CYP2SBSTD and M50CYP2SB1U dimensions Figure 8 Intel Server Board M50CYP2SBSTD a...

Страница 25: ...Intel Server Board M50CYP2SB Family Technical Product Specification 25 2 4 Server Board Mechanical Drawings Figure 9 Intel Server Board M50CYP2SB Family Top Surfaces Keep Out Zone drawing 1...

Страница 26: ...Intel Server Board M50CYP2SB Family Technical Product Specification 26 Figure 10 Intel Server Board M50CYP2SB Family Top Surface Keep Out Zone drawing 2...

Страница 27: ...Intel Server Board M50CYP2SB Family Technical Product Specification 27 Figure 11 Intel Server Board M50CYP2SB Family Bottom Surface Keep Out Zone drawing 1...

Страница 28: ...Intel Server Board M50CYP2SB Family Technical Product Specification 28 Figure 12 Intel Server Board M50CYP2SB Family Bottom Surface Keep Out Zone drawing 2...

Страница 29: ...Intel Server Board M50CYP2SB Family Technical Product Specification 29 Figure 13 Intel Server Board M50CYP2SB Family Components Position drawing 1...

Страница 30: ...Intel Server Board M50CYP2SB Family Technical Product Specification 30 Figure 14 Intel Server Board M50CYP2SB Family Components Position drawing 2...

Страница 31: ...Intel Server Board M50CYP2SB Family Technical Product Specification 31 Figure 15 Intel Server Board M50CYP2SB Family Holes Position...

Страница 32: ...processor family Intel C621A Platform Controller Hub PCH chipset and ASPEED AST2500 Server Management Processor The following figure provides an overview of the Intel Server Board M50CYP2SBSTD archit...

Страница 33: ...ew of the Intel Server Board M50CYP2SB1U architecture showing the features and interconnects of the major subsystem components Figure 3 provides a general overview of the physical server board identif...

Страница 34: ...ssor socket and secure it to the server board Processor cooling options in a server system may use a passive or active heat sink that use airflow to dissipate heat generated by the processors Other pr...

Страница 35: ...f these components It is the responsibility of the system architect or system integrator who chooses to develop their own server system using an Intel server board and a non Intel chassis to consult r...

Страница 36: ...ign power TDP limit of 270 W Processor shelves within the product family are identified as shown in the following figure Figure 19 3rd Gen Intel Xeon Scalable Processor Identification Note Supported 3...

Страница 37: ...ecifications and product briefs for additional information 3 3 1 Supported Technologies The 3rd Gen Intel Xeon Scalable processors combine several key system components into a single processor package...

Страница 38: ...nfiguration the processor must be installed into the processor socket labeled CPU_0 Note Some server board features may not be functional unless a second processor is installed For the Intel Server Bo...

Страница 39: ...3rd Generation Intel Xeon Scalable processors may be populated with a combination of both DDR4 DRAM DIMMs and Intel Optane persistent memory 200 series modules Note Previous generation Intel Optane pe...

Страница 40: ...Oct Rank OR LRDIMMs organized as Quad Rank QR 3DS LRDIMM organized as Quad Rank QR or Oct Rank OR The following tables list the DDR4 DIMM support guidelines Table 4 Supported DDR4 DIMM Memory Type Ra...

Страница 41: ...ers a unique combination of affordable large memory capacity and data persistence non volatility It represents a new class of memory and storage technology architected specifically for data center usa...

Страница 42: ...Mode In App Direct mode applications and the operating system are explicitly aware that there are two types of direct load store memory in the platform They can direct which type of data read or write...

Страница 43: ...n F2 BIOS Setup 4 3 Memory Population On the server board a total of 32 memory slots are provided two slots per channel and eight channels per processor This section provides memory population rules a...

Страница 44: ...inimum Like DIMMS will have matching DIMM attributes as listed in the table below However the DIMM model revision or vendor may be different For warranty replacement Intel will make every effort to sh...

Страница 45: ...populated Processor sockets are self contained and autonomous However all memory subsystem support such as memory RAS and error management in the BIOS Setup are applied commonly for each installed pr...

Страница 46: ...essor Shelf Intel Optane Persistent Memory 200 Series Capacity GB Speed MT s Silver 4300 processors Silver 4314 processor SKU only 128 256 512 2666 2400 Gold 5300 processors 128 256 512 2933 2666 2400...

Страница 47: ...mended population configurations Figure 26 Memory Slot Identification Table 9 Standard DDR4 DIMM Only per Socket Population Configurations of DIMMs IMC2 IMC3 IMC1 IMC0 CH F CH E CH H CH G CH C CH D CH...

Страница 48: ...AM PMem DRAM DRAM DRAM DRAM 12 DRAM 2 PMem AD DRAM DRAM DRAM DRAM PMem DRAM DRAM DRAM DRAM PMem DRAM DRAM DRAM DRAM DRAM DRAM DRAM DRAM PMem DRAM DRAM DRAM DRAM PMem DRAM DRAM DRAM DRAM Note AD App Di...

Страница 49: ...Patrol Scrubbing Demand scrubbing is the ability to write corrected data back to the memory once a correctable error is detected on a read transaction Patrol scrubbing proactively searches the system...

Страница 50: ...emory 200 Series RAS Features Memory RAS Feature Description DIMM Error Detection and Correction Protects against random bit failures across media devices DIMM Device Failure Recovery Single Device Da...

Страница 51: ...features Intel SGX Intel TME and Intel TME MT Feature Technology Intel SGX Intel TME Intel TME MT Intel Optane persistent memory 200 series No No ADC SR ADDDC MR No Yes MCA Recovery Execution Path No...

Страница 52: ...cludes a dedicated management port and support for two system management tiers and optional system management software Standard management features Included Advanced management features Optional Intel...

Страница 53: ...eeded 5 For an IPv6 network o If configuring the server management BMC LAN scroll to Baseboard LAN IPv6 configuration IP source and then select Enabled Then scroll to IPV6 source and select either Sta...

Страница 54: ...e supports keyboard video and mouse redirection KVM over LAN This feature is available remotely from the embedded web server as an HTML5 application USB1 1 or USB 2 0 based mouse and keyboard redirect...

Страница 55: ...web console allows administrator to view system information including firmware versions server health diagnostic information power statistics The web console enables configuration of the BMC and BIOS...

Страница 56: ...of interfaces used by system administrators for out of band management of computer systems and monitoring of their operation 5 2 5 Out of Band BIOS BMC Update and Configuration The BMC supports Redfi...

Страница 57: ...l DCM o Intel Data Center Manager Intel DCM is a software solution that collects and analyzes the real time health power and thermals of a variety of devices in data centers helping to improve the eff...

Страница 58: ...ion and over the workstation s network Each BMC makes a direct network file share connection to the file server and accesses files across that network share directly 5 3 3 Active Directory support The...

Страница 59: ...ard The appendix provides a list of manufacturers and part numbers 6 1 Power Connectors The server board includes several power connectors that are used to provide DC power to various devices 6 1 1 Ma...

Страница 60: ...B8 GROUND A8 GROUND B9 GROUND A9 GROUND B10 P12V A10 P12V B11 P12V A11 P12V B12 P12V A12 P12V B13 P12V A13 P12V B14 P12V A14 P12V B15 P12V A15 P12V B16 P12V A16 P12V B17 P12V A17 P12V B18 P12V A18 P12...

Страница 61: ...figure Table 15 provides the connector pinout On the server board this connector is labeled HSBP PWR The connector manufacturer is Foxconn Interconnect Technology Limited manufacturer part number is...

Страница 62: ...the connectors may be routed to a power in connector on the given add in card Maximum power draw for each connector is 225 W Maximum power is also limited by available power provided by the power supp...

Страница 63: ...onnector supports 3 3 5 12 volts On the server board this connector is labeled Peripheral_ PWR See the following figure for the location of the connector The following table provides the pinout The co...

Страница 64: ...0 5SH Figure 36 Front Panel Header and Front Control Panel Header 6 2 1 Front USB 3 0 2 0 Panel Header The Front USB 3 0 2 0 Panel header is 26 pins The following table provides the pinout Table 18 F...

Страница 65: ...SPARE 19 STATUS_LED_G_N 7 CHASSIS_INTRUSSION 20 P3V3 8 ID_BTN_N 21 ID_LED_N 9 GND 22 PWR_LED_N 10 SMB_SCL 23 P5V_AUX 11 SMB_SDA 24 SPARE 12 RST_BTN_N 25 P3V3_AUX 13 NIC1_LINK_ACT_LED_N 26 P3V3_AUX 6...

Страница 66: ...ND KEY 6 4 I2 C Connectors The server board contains two I2 C connectors The header locations are shown in Figure 38 and the pinout is provided in Table 21 The I2 C header manufacturer is Wieson Techn...

Страница 67: ...ure 39 8 Pin Fan Connector Intel Server Board M50CYP2SBSTD and M50CYP2SB1U Table 22 8 Pin Fan Connector Pinout Intel Server Board M50CYP2SBSTD and M50CYP2SB1U Pin Signal Name Pin Signal Name 8 FAN PRS...

Страница 68: ...er part number is HF2704E M1 Figure 41 CPU 0 CPU 1 Fan Connectors Table 24 CPU 0 CPU 1 Fan Pinout Pin Signal Name 1 GND 2 12V 3 Tach Sense 4 PWM Control 6 6 PCIe SlimSAS Connector To support PCIe NVMe...

Страница 69: ...ND A2 PERp 0 B2 PETp 0 A3 PERn 0 B3 PETn 0 A4 GND B4 GND A5 PERp 1 B5 PETp 1 A6 PERn 1 B6 PETn 1 A7 GND B7 GND A8 BP_TYPE B8 HP_SMB_CLK A9 SSD_ID0 B9 HP_SMB_DAT A10 GND B10 GND A11 CLK_100M_P B11 PE_R...

Страница 70: ...4 B2 PETp 4 A3 PERn 4 B3 PETn 4 A4 GND B4 GND A5 PERp 5 B5 PETp 5 A6 PERn 5 B6 PETn 5 A7 GND B7 GND A8 BP_TYPE B8 SMB_ALERT_N A9 SSD_ID1 B9 CPU 0 FM_SASM_CPU0_N CPU 1 RSVD A10 GND B10 GND A11 CLK_100M...

Страница 71: ...ND A2 PERp 0 B2 PETp 0 A3 PERn 0 B3 PETn 0 A4 GND B4 GND A5 PERp 1 B5 PETp 1 A6 PERn 1 B6 PETn 1 A7 GND B7 GND A8 BP_TYPE B8 HP_SMB_CLK A9 SSD_ID2 B9 HP_SMB_DAT A10 GND B10 GND A11 CLK_100M_P B11 PE_R...

Страница 72: ...4 B2 PETp 4 A3 PERn 4 B3 PETn 4 A4 GND B4 GND A5 PERp 5 B5 PETp 5 A6 PERn 5 B6 PETn 5 A7 GND B7 GND A8 BP_TYPE B8 SMB_ALERT_N A9 SSD_ID3 B9 CPU 0 RSVD CPU 1 FM_SASM_CPU1_N A10 GND B10 GND A11 CLK_100M...

Страница 73: ...r Port 1A 1D x16 4 0 Riser Slot 1 15 0 Port 2A 2D x16 4 0 Riser Slot 1 31 16 Port 3A 3D x16 4 0 Server board PCIe SlimSAS connectors DMI3 x4 3 0 PCH chipset CPU 1 Port 0A 0D x16 4 0 Riser Slot 3 15 0...

Страница 74: ...iser card provide additional add in card support for the server system The PCIe interposer riser card shown in the following figure is an accessory option supported by the PCIe Interposer Riser Slot T...

Страница 75: ...B27 Spare A28 GND B28 GND 7 3 1 PCIe Interposer Riser Card Usage in an Intel Server System M50CYP1UR Family The PCIe Interposer card s functionality depends on the PCIe riser card in Riser Slot 2 The...

Страница 76: ...r Description Connector Description Slot1_PCIe_x16 CPU 1 Ports 2A 2D x16 electrical x16 mechanical PCIe_SSD_0 1 CPU 1 Ports 1A 1B x8 electrical x8 mechanical Note The PCIe Interposer cable must not be...

Страница 77: ...roller supports up to eight 6 GB s SATA III ports on the server board The following table describes the SATA and sSATA feature support Table 33 SATA and sSATA Controller Feature Support Feature Descri...

Страница 78: ...TA Ports on Server Board 8 1 2 SATA Support Through M 2 Connectors Refer to Section 8 2 8 1 3 Staggered Disk Spin Up A high density of hard drives can be attached to the Intel C621A PCH chipset onboar...

Страница 79: ...for RAID to meet the needs of the end user AHCI support provides higher performance and alleviates disk bottlenecks by taking advantage of the independent DMA engines that each SATA port offers in the...

Страница 80: ...s feature set is kept simple to keep size to a minimum but allows the user to create and delete RAID volumes and select recovery options when problems occur The user interface can be accessed by press...

Страница 81: ...erial attached SCSI SAS 4 standard The server board includes eight x4 PCIe SlimSAS connectors These connectors can be used to connect the server board to NVMe drives PCIe lanes from CPU 0 and CPU 1 ar...

Страница 82: ...abled disabled in BIOS Setup at x4 lane granularity Driver sets up manages the domain enumerate event error handling May load an additional child device driver that is Intel VMD aware Hot plug support...

Страница 83: ...Port 3D CPU1_PCIe _PortD In BIOS Setup the Intel VMD support menu is on the following menu tab Advanced PCI Configuration Volume Management Device 8 3 3 Intel Virtual RAID on Chip Intel VROC for NVMe...

Страница 84: ...C VROCSTANMOD Premium Intel VROC 7 5 Key iPC VROCPREMMOD Intel SSD Only VROC 7 5 Key iPC VROCISSDMOD Processor attached NVMe SSD high performance Yes Yes Yes Boot on RAID volume Yes Yes Yes Third part...

Страница 85: ...ial Port A and Serial Port B Serial Port A is described below For Serial Port B see Section 6 3 Serial Port A is an external RJ45 type connector on the back edge of the server board The Serial Port A...

Страница 86: ...6 SIN 3 SOUT 7 DCD or DSR 4 GROUND 8 CTS Note Pin 7 of the RJ45 Serial Port A connector is configurable to support either a DSR default signal or a DCD signal The Pin 7 signal is changed by moving th...

Страница 87: ...The following table provides the pinout for each connector The connector manufacturer is Foxconn Interconnect Technology Limited manufacturer part number is UEA11123 4HK3 4H Figure 55 External USB 3...

Страница 88: ...tion The following table provides the pinout The internal Type A connector does not require 5 V Aux as it does not connect to a Human Interface Device HID The Serial Port A connector manufacturer is F...

Страница 89: ...support the desired video operation when an add in video card is installed When both the Onboard Video and Add in Video Adapter options are set to Enabled both video displays can be active The onboar...

Страница 90: ...s not active until the operating system environment is loaded 9 4 Intel Ethernet Network Adapter for OCP Support The server board supports several types of Intel Ethernet Network Adapters The adapters...

Страница 91: ...hapter provides information on diagnostic LEDs on the server board The following figure shows the location of the LEDs on the server boards post code diagnostic LEDs system ID LED CPU 0 and CPU 1 faul...

Страница 92: ...0 2 System ID LED The server board includes a blue system ID LED that is used to visually identify a specific server system installed among many other similar systems Note In an Intel Server System M5...

Страница 93: ...t power supply configuration was present Unable to use all installed memory more than 1 DIMM installed Correctable Errors over a threshold and migrating to a spare DIMM memory sparing This indicates t...

Страница 94: ...stem ID LED are used to indicate BMC boot process transitions and states if present A BMC boot occurs when the AC power is first applied DC power on off does not reset BMC BMC reset occurs after a BMC...

Страница 95: ...MSID mismatch 10 6 Memory Fault LEDs The server board includes memory fault LEDs for each DIMM slot see following figure When the BIOS detects a memory fault condition it sends an IPMI OEM command Set...

Страница 96: ...or has a lower critical threshold event status asserted Fan tach sensors are manual re arm sensors Once the lower critical threshold is crossed the LED remains lit until the sensor is re armed These s...

Страница 97: ...family the BMC controls the system status LED and chassis ID LED It supports secure lockout of certain front panel functionality and monitors button presses The chassis ID LED is turned on using a fr...

Страница 98: ...T display However pressing Esc hides the logo screen and displays the diagnostic screen instead during the current boot If a logo is not present in the BIOS flash memory space or if Quiet Boot is disa...

Страница 99: ...an updated one Full BIOS update instructions are provided with update packages downloaded from the Intel website 11 2 Field Replaceable Unit FRU and Sensor Data Record SDR Data As part of the initial...

Страница 100: ...ckout Intel Platform Firmware Resilience Intel PFR Intel Software Guard Extensions Intel SGX Intel Total Memory Encryption Intel TME Trusted Platform Module TPM support Intel CBnT Converged Intel Boot...

Страница 101: ...entered a warning message is displayed and the weak password is accepted Once set a password can be cleared by changing it to a null string This action requires the administrator password and must be...

Страница 102: ...nd disruptive impact of security attacks continue to escalate data centers are driving a holistic approach to protect their critical infrastructure This includes protecting server systems at the firmw...

Страница 103: ...class algorithm for encryption AES XTS Transparent to software it encrypts data before writing to server memory and then decrypts on read Easy enablement that requires no operating system or applicati...

Страница 104: ...n in protection against physical attacks no integrity anti replay protections vs other Intel SGX variants Designed for environments where the physical environment is still trusted Note Intel SGX can o...

Страница 105: ...s and to clear TPM ownership For additional details see the TCG PC Client Specific Implementation Specification the TCG PC Client Specific Physical Presence Interface Specification and the Microsoft W...

Страница 106: ...ing system loader or a UEFI driver stored in an option ROM This situation provides the capability to ensure that those UEFI images are only loaded in an owner authorized fashion and provides a common...

Страница 107: ...ets BIOS options configured using the F2 BIOS Setup Utility back to their original default factory settings Note This jumper does not reset administrator or user passwords To reset passwords the passw...

Страница 108: ...r from pins 1 2 default to pins 2 3 password clear position 5 Reinstall the system top cover 6 Reattach the power cord s 7 Power up the server and press F2 to access the BIOS Setup utility 8 Verify th...

Страница 109: ...er 16 Reattach the power cord s 17 Power on the system 13 4 BMC Force Update Jumper BMC FRC UPD J20 The BMC force update jumper is used to put the BMC in boot recovery mode for a low level update It c...

Страница 110: ...r version of BIOS server systems may end up with a firmware stack combination that is not supported and therefore could experience unpredictable behavior Note Latest system update packages are include...

Страница 111: ...ckages are included in the SUP posted to Intel s download center website at http downloadcenter intel com To use the BMC_SVN_DG Downgrade switch perform the following steps 1 Remove the chassis top co...

Страница 112: ...using one of the support phone numbers available at https www intel com content www us en support contact support html charges may apply Intel also offers Partner Alliance Program members around the...

Страница 113: ...board the add in card or both For the best performance the number of DDR4 DIMMs installed should be balanced across both processor sockets and memory channels On the back edge of the server board the...

Страница 114: ...the last POST routine that was run before the error occurring helping to isolate the possible cause of the hang condition Each POST code is represented by eight LEDs four green LEDs and four amber LE...

Страница 115: ...each step Table 46 Memory Reference Code MRC Progress Codes Post Code Hex Upper Nibble Lower Nibble Description 8h 4h 2h 1h 8h 4h 2h 1h B0 1 0 1 1 0 0 0 0 Detect DIMM population B1 1 0 1 1 0 0 0 1 Se...

Страница 116: ...Upper Nibble Lower Nibble Description 8h 4h 2h 1h 8h 4h 2h 1h E8 1 1 1 0 1 0 0 0 No usable memory error 01h No memory was detected from SPD read or invalid config that causes no operable memory 02h M...

Страница 117: ...8 1 0 1 0 1 0 0 0 Program final route A9 1 0 1 0 1 0 0 1 Program final IO SAD setting AA 1 0 1 0 1 0 1 0 Protocol layer and other uncore settings AB 1 0 1 0 1 0 1 1 Transition links to full speed oper...

Страница 118: ...1 0 1 0 Internal Use CB 1 1 0 0 1 0 1 1 Check RAS support CC 1 1 0 0 1 1 0 0 Pmem ADR Init CD 1 1 0 0 1 1 0 1 Internal Use CE 1 1 0 0 1 1 1 0 Memory Late Init CF 1 1 0 0 1 1 1 1 Determine MRC boot mod...

Страница 119: ...CSI begin A6 1 0 1 0 0 1 1 0 DXE SCSI reset A7 1 0 1 0 0 1 1 1 DXE SCSI detect A8 1 0 1 0 1 0 0 0 DXE SCSI enable AB 1 0 1 0 1 0 1 1 DXE SETUP start AC 1 0 1 0 1 1 0 0 DXE SETUP input wait AD 1 0 1 0...

Страница 120: ...he system continues booting in a degraded state The user may want to replace the erroneous unit The POST Error Pause option setting in the BIOS Setup does not affect this error Major An error message...

Страница 121: ...ed Major 8131 CPU 1 disabled Major 8160 CPU 0 unable to apply microcode update Major 8161 CPU 1 unable to apply microcode update Major 8170 CPU 0 failed Self Test BIST Major 8171 CPU 1 failed Self Tes...

Страница 122: ...Major 8536 Memory failed test initialization CPU0_DIMM_H2 Remove the disabled DIMM Major 8537 Memory failed test initialization CPU0_DIMM_H3 Remove the disabled DIMM Major 8538 Memory failed test ini...

Страница 123: ...disabled DIMM Major 8560 Memory encountered a Serial Presence Detection SPD failure CPU0_DIMM_A1 Major 8561 Memory encountered a Serial Presence Detection SPD failure CPU0_DIMM_A2 Major 8562 Memory en...

Страница 124: ...ajor 857F Go to 85E0 Memory encountered a Serial Presence Detection SPD failure CPU1_DIMM_C2 Major 85C0 Memory failed test initialization CPU1_DIMM_C3 Remove the disabled DIMM Major 85C1 Memory failed...

Страница 125: ...SPD failure CPU1_DIMM_D1 Major 85E2 Memory encountered a Serial Presence Detection SPD failure CPU1_DIMM_D2 Major 85E3 Memory encountered a Serial Presence Detection SPD failure CPU1_DIMM_D3 Major 85...

Страница 126: ...he memory was detected 3 long and 1 short CPU mismatch error E5 E6 System halted because a fatal error related to the CPU family core cache mismatch was detected The integrated BMC may generate beep c...

Страница 127: ...o the SEL If the BIOS Setup option Post Error Pause is enabled operator intervention is required to continue booting the system If the BIOS Setup option POST Error Pause is disabled the system continu...

Страница 128: ...highest common frequency Does not generate an error this is not an error condition Continues to boot the system successfully If the link frequencies for all Intel UPI links cannot be adjusted to be t...

Страница 129: ...e persistence of information written to each component is determined by its type as described in the table Each component stores data specific to its function Some components may contain passwords tha...

Страница 130: ...al Connector RJ45 Foxconn Interconnect Technology Limited JMP1N07 RKM01 4H I O 26 Pin FPC connector for front USB panel interface Hirose Electric U S A Inc FH34SRJ 26S 0 5SH I O 26 Pin FPC connector f...

Страница 131: ...Appendix G Sensors The following figure provides the location of the sensors on the Intel Server Boards M50CYP2SB1U and M50CYP2SBSTD The following table provides a list of the sensors Note The numbers...

Страница 132: ...sor 1 DIMM Aggregate Thermal Margin 2 DIMM Thrm Mrgn 2 B2h Processor 1 DIMM Aggregate Thermal Margin 3 DIMM Thrm Mrgn 3 B3h Processor 1 DIMM Aggregate Thermal Margin 4 DIMM Thrm Mrgn 4 B4h Processor 2...

Страница 133: ...r 1 Temp 60h M2 Left Margin 61h M2 Right Margin 22h SSB Temperature SSB Temp 24h Baseboard Temperature 3 BB BMC Temp 25h Baseboard Temperature 3 BB M 2 Temp 26h Baseboard Temperature 5 BB OCP Temp 27h...

Страница 134: ...he chassis add or remove any components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the server and disco...

Страница 135: ...ir edges only After removing electronic devices from the system or from their protective packaging place them component side up on to a grounded anti static surface or conductive workbench pad Do not...

Страница 136: ...hods for securing the server board to the chassis The selected chassis may have integrated mounting features or they may include separate mounting stand offs that must be installed The following illus...

Страница 137: ...onnectors found on the back edge of the server board Figure 68 Server Board Rear I O Connectors Most extended ATX server chassis will include a standard sized cut out on the back panel that allows for...

Страница 138: ...edures then Intel recommends following the processor replacement procedures included within documentation supplied with the chosen non Intel server system Components Required New matching 3rd Gen Inte...

Страница 139: ...l four heat sink anti tilt wires are in the outward position see Letter A 5 Then fully unscrew all four heat sink fasteners in any order see Letter B 6 Set all four anti tilt wires on the heat sink to...

Страница 140: ...grips Ensure socket cover is locked in place Caution Do not press the center of the socket cover Figure 73 Processor Removal from PHM Assembly 10 Place the PHM bottom side up on a flat surface 11 Whi...

Страница 141: ...the server board the procedures described in the following sections must be followed in the order specified These instructions assume that all the PHM components are new and the Thermal Interface Mat...

Страница 142: ...arrier clip is aligned with the Pin 1 indicator of the processor Figure 76 Installing Processor Carrier Clip onto Processor Part 2 3 Gently press down on two opposite sides at a time of the processor...

Страница 143: ...tective film from the Thermal Interface Material TIM Figure 79 Pin 1 Indicator of Processor Carrier Clip 8 Align Pin 1 indicator of processor carrier clip with the corner cut out on the heat sink Note...

Страница 144: ...Socket Protective Cover Removal 1 Remove the protective cover by squeezing the finger grips see Letter A and pulling the cover up see Letter B 2 Ensure the socket is free of damage or contamination be...

Страница 145: ...5 Holding the PHM horizontally carefully lower it on to the bolster plate s alignment pins see Letter B 6 Set all four anti tilt wires on the heat sink to the outward position see Letter C Figure 83 T...

Страница 146: ...source before replacing a faulty memory module from the system Instructions to physically replace a DDR4 DIMM or an Intel Optane PMem 200 series module are the same For the following procedure Standar...

Страница 147: ...e memory module with the key in the memory slot see Letter B 8 Insert the memory module into the memory slot Using even pressure along the top edge push down on the memory module see Letter C until th...

Страница 148: ...rovide a high level overview of the features associated with each For additional product information refer to the Technical Product Specification Integration and Service Guide Product Family Configura...

Страница 149: ...memory channels per processor o Two DIMMs per channel All DDR4 DIMMs must support ECC Registered DDR4 RDIMM 3DS RDIMM Load Reduced DDR4 LRDIMM 3DS LRDIMM Note 3DS 3 Dimensional Stacking Intel Optane p...

Страница 150: ...FL single width slot x16 electrical x16 mechanical one FH FL single width slot x8 electrical x16 mechanical one FH HL single width slot x8 electrical x8 mechanical iPC CYP2URISER2STD Riser Slot 3 Ris...

Страница 151: ...ment Controller BMC o 2D Video Graphics Adapter System Configuration and Recovery Jumpers BIOS load defaults BIOS Password clear Intel Management Engine firmware force update Jumper BMC force update B...

Страница 152: ...el Xeon Silver 4300 processor Note Supported 3rd Gen Intel Xeon Scalable processor SKUs must Not end in H L U Q or M All other processor SKUs are supported Intel UPI links up to three at 11 2 GT s Pla...

Страница 153: ...system fans Integrated fans included with each installed power supply module Note System fan redundancy is supported on specific system configurations Power Supply Options The server system can have...

Страница 154: ...SlimSAS connector on the PCIe riser card The Intel accessory kit includes the PCIe interposer riser card PCIe riser card and PCIe interposer cable iPC CYP1URISER2KIT Riser Slot 3 Riser Slot 3 support...

Страница 155: ...el Management Engine firmware force update Jumper BMC force update BIOS_SVN Downgrade BMC_SVN Downgrade For more information see the Intel Server Board M50CYP2SB Family Technical Product Specification...

Страница 156: ...amily Intel Server System M50CYP2UR Family Notes Coyote Pass 2U Coyote Pass Intel Project Code Name L3 Board L6 L9 System Product integration level M50CYP M500002UR M500001UR Product family identified...

Страница 157: ...tem M50CYP1UR Family System Integration and Service Guide https www intel com content www us en support products 200321 html Product Specifications o Intel Server Board M50CYP2SB Family Technical Prod...

Страница 158: ...DDR4 Double Data Rate 4 DHCP Dynamic Host Configuration Protocol DIMM Dual In line Memory Module DPC DIMMs per Channel DR Dual Rank EATX Extended Advanced Technology eXtended EDS External Design Spec...

Страница 159: ...tection OVP Over voltage Protection PCH Peripheral Controller Hub PCI Peripheral Component Interconnect PCB Printed Circuit Board PCIe Peripheral Component Interconnect Express PFC Power Factor Correc...

Страница 160: ...Serial over LAN SR Single Rank SSD Solid State Device TCG Trusted Computing Group TDP Thermal Design Power TPM Trusted Platform Module TPS Technical Product Specification Intel TXT Intel Trusted Exec...