Chapter 6
6–2
MiniMate Plus Operator Manual
If required, other AC adapters may be used but must meet the following restrictive specifications.
Minimum Voltage
Required by the
Monitors
Maximum
Output
Maximum No
Load Voltage
(VDC)
Maximum
Power
(VA)
Safety
Rating
(equal to)
Length
of Cord
Plug Style and
Size
11 VDC
less than 13.8
VDC for loads
over 500 mA
18.8 12
maximum
6
recommended
CSA/UL 3
m
(10 ft.)
2.1 mm Coaxial
center post
positive
6.2. Annual Calibration Requirements
Geophone sensors, located inside the MiniMate Plus or inside the Standard Transducer, and the
microphone require annual calibration to ensure continued accurate monitoring results.
Calibration may be performed by an authorized Instantel service facility or by Instantel. Contact
your dealer to arrange to have your MiniMate Plus and its sensors calibrated.
6.3. Cleaning the MiniMate Plus
Vacuum dust, dirt, and sand from the MiniMate Plus. Use isopropyl alcohol to remove stains. Do
not use paint thinners or ketone solvents. These may damage the MiniMate Plus. To avoid
scratching the protective cover and display, do not scrub the surfaces with abrasive material
including cleaning pads.
Содержание 716A0401
Страница 1: ......
Страница 6: ...iv MiniMate Plus Operator Manual Notes...
Страница 12: ...x MiniMate Plus Operator Manual Notes...
Страница 16: ...Chapter 1 1 4 MiniMate Plus Operator Manual 1 4 MiniMate Plus Keys...
Страница 66: ...Chapter 5 5 16 MiniMate Plus Operator Manual Notes...
Страница 71: ...Appendix MiniMate Plus Operator Manual A 1 Appendix...
Страница 72: ...Appendix A 2 MiniMate Plus Operator Manual...
Страница 81: ...Appendix MiniMate Plus Operator Manual A 11 Notes...
Страница 82: ...Appendix A 12 MiniMate Plus Operator Manual...