Chapter 2
2–2
MiniMate Plus Operator Manual
Step 2: Turn the MiniMate Plus On
Press and hold the
Enter
key, located on the MiniMate Plus face panel, until you hear an audible
beep. A Start Up Window displays for three seconds followed by the Main Window display. The
Start Up Window shows the MiniMate Plus serial number, operating software version, amount of
installed memory, whether the memory is empty or full, and the number of events stored in the
MiniMate Plus.
Operating System
Release
Sn BC3074
R 4.0
Figure 2.2 The MiniMate Plus Start Up Window.
The Main Window tells you the MiniMate Plus is ready to monitor. It also indicates battery level,
date, time, and on–line help information. This is your starting window whenever you setup the
MiniMate Plus. From here, you access all setups.
Off
Figure 2.3 The MiniMate Plus Main Window.
Step 3: Check Your Installation
Check your installation by pressing the
Test
key. This executes the Sensorcheck program and
tests the transducer and microphone. The message “All Channels Working. Press Test to
Review Setups” appearing on the display tells you that your installation is level.
Step 4: Review Setups
Before we begin, let us review the current MiniMate Plus setups. To review setups, press the
Option
key and the
Test
key together. The current setups scroll past on the MiniMate Plus
display. You can pause the display by pressing the
Enter
key. To continue the scrolling, press the
Enter
key again.
Step 5: Change the MiniMate Plus Setups
After reviewing the setups, we have decided to change them, specifically the record mode, trigger
source, trigger levels, record stop mode, the time, and the date. To change these setups, follow the
steps below.
a) Change the Record Mode
The MiniMate Plus has five record modes: Single Shot, Continuous, Manual, Histogram and
Histogram Combo. We want to change the record mode from single shot to continuous. Single
shot record mode records one event and stops. In continuous record mode, the MiniMate Plus
records multiple events until you stop monitoring or the memory fills up with recorded events.
Содержание 716A0401
Страница 1: ......
Страница 6: ...iv MiniMate Plus Operator Manual Notes...
Страница 12: ...x MiniMate Plus Operator Manual Notes...
Страница 16: ...Chapter 1 1 4 MiniMate Plus Operator Manual 1 4 MiniMate Plus Keys...
Страница 66: ...Chapter 5 5 16 MiniMate Plus Operator Manual Notes...
Страница 71: ...Appendix MiniMate Plus Operator Manual A 1 Appendix...
Страница 72: ...Appendix A 2 MiniMate Plus Operator Manual...
Страница 81: ...Appendix MiniMate Plus Operator Manual A 11 Notes...
Страница 82: ...Appendix A 12 MiniMate Plus Operator Manual...