MD380 User Manual Function Code Table
- 91 -
F
unction
Code
Parameter Name
Setting Range
Default
Property
F
4-33 AI curve selection
Unit's digit (AI1 curve selection)
321
☆
Curve 1 (2 points, see F4-13 to
F4-16)
Curve 2 (2 points, see F4-18 to
F4-21)
Curve 3 (2 points, see F4-23 to
F4-26)
Curve 4 (4 points, see A6-00 to
A6-07)
Curve 5 (4 points, see A6-08 to
A6-15)
Ten's digit (AI2 curve selection)
Curve 1 to curve 5 (same as AI1)
Hundred's digit (AI3 curve
selection)
Curve 1 to curve 5 (same as AI1)
F
4-34 Setting for AI less than
minimum input
Unit's digit (Setting for AI1 less
than minimum input)
000
☆
0: Minimum value
1: 0.0%
Ten's digit (Setting for AI2 less
than minimum input)
0, 1 (same as AI1)
Hundred's digit (Setting for AI3
less than minimum input)
0, 1 (same as AI1)
F
4-35 DI1 delay time
0.0–3600.0s
0.0s
★
F
4-36 DI2 delay time
0.0–3600.0s
0.0s
★
F
4-37 DI3 delay time
0.0–3600.0s
0.0s
★
F
4-38 DI valid mode selection 1
Unit's digit (DI1 valid mode)
00000
★
0: High level valid
1: Low level valid
Ten's digit (DI2 valid mode)
0, 1 (same as DI1)
Hundred's digit (DI3 valid mode)
0, 1 (same as DI1)
Содержание HD380-5T0.7GB
Страница 1: ...High Performance AC Drive MD380...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions MD380 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information MD380 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples MD380 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions MD380 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...
Страница 298: ...MD380 Series High Performance AC Drive...