Operation, Display and Application Examples
MD380 User Manual
- 60 -
■
Parameter Setting and Operation of JOG Running in DI Terminal Control
For equipment that requires frequent JOG operations, such as textile machine, it
is more convenient to control JOG running by using keys or buttons. To achieve
convenient control, perform the setting according to the following figure.
Figure 4-16 JOG running in DI terminal control
F
4-00
F
4-01
F
4-02
F
4-03
F
4-04
.
.
.
.
4
5
.
F
0-02 = 1
JOG control
button
Terminal
Function
value
Setting
value
DI1
DI2
DI3
DI4
DI5
.
COM
Forward
JOG
Terminal
control
Parameter setting
Forward
JOG
Reverse
JOG
FJOG
RJOG
Reverse
JOG
F
8-00 (JOG running frequency)
F
8-01 (JOG acceleration time )
F
8-02 (JOG deceleration time)
Forward
JOG
Reverse
JOG
(Stop state)
F
8-13 = 1
After performing the setting according to the preceding figure, press the FJOG button
in stop state of the AC drive. Then, the AC drive starts forward JOG. After you press the
FJOG button again, the AC drive decelerates to stop.
4.8 Setting the Running
F
requency
The AC drive provides two frequency sources, namely, main frequency source X and
auxiliary frequency source Y. You can select one frequency source and switch over between
the two sources. You can also perform superposition on the two sources by setting the
calculation formula to meet different control requirements of different scenarios.
4.8.1
F
requency Setting by the Main
F
requency Source
There are nine setting modes of main frequency sources, digital setting (UP/DOWN
modification, non-retentive at power failure), digital setting (UP/DOWN modification,
retentive at power failure), AI1, AI2, AI3, pulse setting, multi-reference, simple PLC, and
communication setting. You can select one in F0-03.
Figure 4-17 Frequency set by the main frequency source
F
0-03 (Main
frequency
source X
selection)
0
0-10 V
1
▲
▼
Retentive at
power failure
4-20 m A
J8
F
0 -08
AI1
AI2
AI3
On extension
board
F
4-04 = 30
DI5
Pulse
setting
2
3
4
5
F
4- 00
to F
4- 04
= 12 /13 /14/ 15
M ulti- speed
6
Analog
Analog
DI1 to DI10
F C
- 00
to F C
-15
(each
frequency )
Group F C
Sim ple PLC
Group F A
PID
H1000 register
Com m unication
setting
Host
computer
7
8
9
AI1 to AI2
F
4 -33
F
4-29 to
F
4- 32
Analog
F D
-00
to F D
-05
Com m unication
configuration
DI5 (f)
Digital
setting
Main
frequency
source X
F
4-00 to
F
4-09 = 39
DI1 to DI10
Frequency
switchover
F
0-08
0 -10 V
-10 V to 10 V
F
4- 33
F
4 -33
Содержание HD380-5T0.7GB
Страница 1: ...High Performance AC Drive MD380...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions MD380 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information MD380 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples MD380 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions MD380 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...
Страница 298: ...MD380 Series High Performance AC Drive...